10
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts
AutoDome Pendant Arm Mount
2.1.4
Description
This chapter details how to install an AutoDome Pendant Arm to a wall, a corner, or to a mast
(pole). Any variations to the installation procedures are noted.
Note
: You may need to purchase additional mounting accessories for corner and mast mount
applications. Refer to
Section 2.1.2 Optional Mounting Accessories, page 9
.
2.1.5
Tools Required
–
5 mm Allen wrench (supplied)
–
Small, straight-blade screwdriver - 2.5 mm (0.1 in.)
–
No. 2 Phillips screwdriver
–
Socket wrench and 9/16-in. socket
–
Banding tool (Bosch P/N TC9311PM3T) - if installing a mast (pole) mount
–
3/4 in. (20-mm) NPS right angle conduit connector - if installing a mast (pole) mount
2.2
Pre-installation Checklist
1. Determine the location and distance of the AutoDome from the power supply based on
its voltage and current consumption.
Refer to
Section 3 Cable and Wire Standards, page 19
, for wiring information and
distances.
2. Use only UL listed liquid tight strain reliefs for conduits from the power supply to
pendant arm to ensure that water cannot enter system. You must use water tight
conduits and fittings to meet NEMA 4 standards.
WARNING!
Power and I/O cabling must be routed separately inside different permanently earthed metal
conduits.
3. Route all rough wiring including: power, control, video coax, alarms I/O, relay I/O, and
fiber optic cabling. Refer to
Section 3 Cable and Wire Standards, page 19
, for video and
control protocol methods.
4.
Analog AutoDome
: If you plan to use the RS232 or RS485 protocol to control the
AutoDome, refer to
Section 3.4.2 Controlling the AutoDome via the RS232 Protocol,
page 24
, for instructions on configuring the AutoDome to accept these protocols.
WARNING!
Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
5. Choose the appropriate AutoDome model (indoor or outdoor) for the environment in
which it will be used.
6. Purchase the appropriate mounting hardware to use, depending on the location of the
AutoDome, either wall mount, corner mount, or mast (pole) mount.
CAUTION!
Select a rigid mounting location to prevent excessive vibration to the AutoDome camera.
F.01U.250.238 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
Содержание VGA-PEND-ARM
Страница 2: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 33: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 34: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 35: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...