(3-wire, full-duplex, single-ended, 50 ft. cable limit)
RS232 is a common, single-ended communication protocol used for control. Data
transmission via 3-wires (TDX, RXD, common) is from one transmitter to one receiver at
relatively slow baud rates (up to 57.6 Kbaud) and short distances up to 50 ft. This control
option is applicable to VG5 600 Series AutoDomes only.
NOTICE!
After making the wire connections for RS232 operation, reposition the slide switch located on
the CPU Module to the camera head inward and away from the LEDs.
Wire Type
3-wire (TXD, RXD, common)
Distance
15 m (50 ft)
Maximum Baud Rate
57.6 Kb
Voltage
± 15 V
Termination
100 Ω
Slide Switch
Away from LEDs (factory default)
Figure 3.4
1
2
3
4
5
6
Connections for RS232 Operation
C- (Biphase)
C+ (Biphase)
Earth Ground
RxD
TxD
Signal Ground
7
8
9
10
11
12
AutoDome Data In/Out
P105/P106 Connector
Head End RS232
TxD
RxD
Ground
F.01U.250.238 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
Содержание VGA-PEND-ARM
Страница 2: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 33: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 34: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...
Страница 35: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...