58 | Service reminder
Error no .
Error
Description
106
REFHI_TOO_HIGH
Internal software error
107
REFHI_TOO_LOW
Internal software error
108
REFLO_TOO_HIGH
Internal software error
109
REFLO_TOO_LOW
Internal software error
110
REFHI2_TOO_HIGH
Internal software error
111
REFHI2_TOO_LOW
Internal software error
112
REFLO2_TOO_HIGH
Internal software error
113
REFLO2_TOO_LOW
Internal software error
114
FALSE_FLAME
Flame is detected in a state in which no flame is allowed to be seen
115
LOW_WATER_PRESSURE_ERROR
Low water pressure error
116
LOW_WATER_PRESSURE_SENSOR
Low water pressure
117
BLOCKED_DRAIN
Block drain switch is active
118
WD_COMM_ERROR
Watchdog communication error
119
RETURN_OPEN
Return sensor open
120
SUPPLY_OPEN
Supply sensor open
121
SUPPLY2_OPEN
Supply 2 sensor open
122
DHW_OPEN
DHW sensor open
123
FLUE_OPEN
Flue sensor open
124
FLUE2_OPEN
Flue 2 sensor open
125
OUTDOOR_OPEN
Outdoor sensor open
126
RETURN_SHORTED
Return sensor shorted
127
SUPPLY_SHORTED
Supply sensor shorted
128
SUPPLY2_SHORTED
Supply 2 sensor shorted
129
DHW_SHORTED
DHW sensor shorted
130
FLUE_SHORTED
Flue sensor shorted
131
FLUE2_SHORTED
Flue 2 sensor shorted
132
OUTDOOR_SHORTED
Outdoor sensor shorted
133
RESET_BUTTON_ERROR
Too many resets in a short time period
134
PHASE_NEUTRAL_RESERVED_ERROR
The live and neutral of the main voltage power supply input are reversed
135
T_EXCHANGE_BLOCK_ERROR
Exchange temperature exceeded 90°C.
136
T_CHIMNEY_OPEN
Chimney sensor open
137
T_EXCHANGE1_OPEN
Exchange 1 sensor open
138
T_EXCHANGE2_OPEN
Exchange 2 sensor open
139
T_SELECTION1_OPEN
Selection 1 sensor open
140
T_SELECTION2_OPEN
Selection 2 sensor open
141
T_SELECTION3_OPEN
Selection 3 sensor open
142
T_OPTIONAL1_OPEN
Optional 1 sensor open
143
T_OPTIONAL2_OPEN
Optional 2 sensor open
144
T_AMBIENT_OPEN
Ambient sensor open
145
T_CHIMNEY_CLOSED
Chimney sensor shorted
146
T_EXCHANGE1_CLOSED
Exchange 1 sensor shorted
147
T_EXCHANGE2_CLOSED
Exchange 2 sensor shorted
148
T_SELECTION1_CLOSED
Selection 1 sensor shorted
149
T_SELECTION2_CLOSED
Selection 2 sensor shorted
150
T_SELECTION3_CLOSED
Selection 3 sensor shorted
151
T_OPTIONAL1_CLOSED
Optional 1 sensor shorted
152
T_OPTIONAL2_CLOSED
Optional 2 sensor shorted
153
T_AMBIENT_CLOSED
Ambient 1 sensor shorted
154
WD_CONFIG_ERROR
Watchdog fan configuration setting error
155
FLUE_PRESSURE_ERROR
Flue pressure switch is closed
156
AIR_DAMPER_ERROR
Air Damper feedback is not received when the relative output is closed
157
T_SECONDARY_SUPPLY_OPEN
Secondary circuit supply sensor open
158
T_SECONDARY_RETURN_OPEN
Secondary circuit return sensor open
159
T_SECONDARY_SUPPLY_CLOSED
Secondary circuit supply sensor shorted
160
T_SECONDARY_RETURN_CLOSED
Secondary circuit return sensor shorted
161
FILL_WARNING
Pressure is too low, demand has stopped, but no error needed to be stored at
this time