Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 110 of 157
6.30
Replacing the drain check valve
Drain check valve is situated in the lower area of the sump.
Prerequisite:
•
Appliance is disconnected from the power supply.
•
Sump has been emptied.
•
furniture panel has been removed (optional).
•
Toe panel has been removed (optional).
•
Base socket plate has been removed.
6.30.1
Removing the drain check valve
1. Press the connecting hose out of the holder (1) and pull out of the connecting
pieces of the sump (2).
2.
Leaks on the connecting pieces due to improper removal!
► Do not use any sharp-edged tools.
► Do not scratch the inside of the connecting pieces.
Turn the drain check valve to the right or the left (< 45°) and remove the drain
check valve from the connecting pieces.