Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 66 of 157
6.10
Replacing the flow-through sensor
The flow meter consists of an impeller and a Reed contact switch.
It is situated on the heat exchanger / water inlet system.
•
A defective impeller can only be replaced as a unit (for example,
a blockage) with a water inlet system / heat exchanger. The Reed
contact switch can be replaced individually.
6.10.1
Removing the Reed contact switch
Prerequisite:
•
Appliance is disconnected from the power supply.
•
Appliance is freely accessible.
•
Left side panel has been removed.
Destruction of the Reed contact switch (glass flask) because of too much
force!
► Do not bend or kink the PCB of the Reed contact switch.
1. Bend the protective cover of the Reed contact switch outwards (1).
2. Disconnect the Reed contact switch (1).