Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 151 of 157
6.49
Replacing the heat exchanger
The heat exchanger is situated on the left-hand side of the tub.
Required tools:
?
Auxiliary tool [ 341313]
Prerequisite:
•
Appliance has been emptied.
•
Appliance is freely accessible.
•
Left side panel has been removed.
•
Flow meter has been removed.
•
Outlet valve has been removed.
6.49.1
Removing the heat exchanger
1. Mark the installation position of the cover cap steam vent in the inside of the
tank with a water-soluble pen.
2. Remove the cover cap steam vent nut and the water inlet supports with the
auxiliary tool.
3. Loosen the hose clamp on the inlet hose and remove the inlet hose.