Fault diagnosis
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 26 of 157
Fault
Possible cause
Troubleshooting
Incorrect connection, or damage to cables
or multiway power sockets (external). Ap-
pliances that are connected to multiway
power sockets must immediately be taken
out of service!
-
The reason must always be established! Only approved extension cables may be
used (see installation instructions)
► Replace the power cable
-
Observe the safety instructions given in the instruction manual.
Faulty plug connections inside the appli-
ance
► Check the cable of the power supply unit and the plug connection to the power
module.
► Check the power module for any faulty components.
► Replace the defective part.
Smell of burning
The reason for this must always be es-
tablished!
Defective housings or damaged cables on
components inside the appliance
► Measure the component’s values and check them against the circuit diagram.
► Check the plug connection.
► Replace the defective part.
New smell
This comes from the bonding material in
the sound insulation (non-woven fabric, in-
sulation mats)
► Advise customer:
The smell is more intensive when the appliance is new. It will disappear with time. If
necessary recommend a fragrance dispenser. There is
no
health risk!
?
Fragrance dispenser [ 460742]