Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 90 of 157
6.22
Replacing the drain pump
The drain pump is installed on the sump.
Prerequisite:
•
Appliance is disconnected from the power supply
•
Appliance has been emptied.
•
Base socket plate has been removed.
•
Toe panel has been removed (optional).
6.22.1
Removing the drain pump
Depending on the design of the basis carrier, greater force is
required to remove the drain pump.
1. Unlock and disconnect electrical connection (1).
2. Pull the catch element forwards (2).
3. Turn the drain pump anticlockwise (3) and remove from the sump (4).
6.22.2
Installing the drain pump
1. Install the drain pump in reverse order.
2.