6.2
Replacing the outlet valve
The outlet valve is situated in the lower area of the heat exchanger.
Prerequisite:
•
Appliance is freely accessible.
•
Appliance is disconnected from the power supply.
•
Appliance has been emptied.
•
Left side panel has been removed.
6.2.1
Removing the outlet valve
1. Release the electrical connection (1) and unplug it (2).
2. Turn the outlet valve to the right (1). Disconnect the outlet valve from the heat
exchanger (2).
6.2.2
Installing the outlet valve
1. Install the outlet valve in reverse order.
2. Check that the heat exchanger is not leaking following installation of the outlet