6.23
Replacing the power module
The power module is situated on the lower right-hand side of the
tub in the basis carrier.
Prerequisite:
•
Appliance is disconnected from the power supply.
•
Mains cable has been removed
•
The right-hand side panel has been removed
•
The insulating mat has been removed
•
Fleet reservoir has been removed (optional).
•
Appliance has been emptied (only relevant for appliances with a fleet
reservoir).
6.23.1
Removing the power module
1. Press the splash water guard upwards at the top left-hand side and remove.
2. Loosen the catch tappets at the top side of the splash water guard (optional)
and tilt it away to the left.
3.
Do not open the coding frames. The coding frames are part of
the cable harness and are removed with the plugs.
Using a screwdriver, remove both coding frames from the contact strip together
with the plugs.