Fig.7-4:
Pin assignment XCOM1 to XCOM3
A safe function of a device connected to a
COM interface is not possible if the COM in‐
terface is already used internally.
NOTICE
A safe function of a device connected to a COM interface is only possible if the
COM interface is not used internally. Depending on the variant and the used
software packages, the interfaces can already be occuppied.
7.2.4
Serial Interfaces, Settings
Control panel
To find out settings of the transfer parameters for the serial interfaces please
refer to the description of the installed operating system. In Windows XP under
Start Settings Control panel Device manager.
BIOS
The BIOS settings of the serial interfaces are:
Interface
BIOS setting
COM1
3F8H
COM2
2F8H
COM3
3E8H
COM4
2E8H
Fig.7-5:
BIOS settings
A safe function of a device connected to a
COM interface is not possible if Interrupt or I/O
address conflicts arise.
NOTICE
Interrupt (IRQ) and I/O address have to correspond to the settings carried out
in BIOS.
If an address conflict regarding COM3 occurs, e. g., IRQ 11 is already occupied
by other extension cards of the PC, free IRQs have to be used.
RS232 interface for IndraControl
VPB 40.1
A new motherboard is used for the the IndraControl devices VPB and VPP type
1 devices. Due to the new motherboard, serial RS232 components may not
function correctly. The reason for this is a change of Interrupt 10 and 11 of the
serial COM interfaces in the serial COM ports 3 and 4. For troubleshooting
DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
Bosch Rexroth AG
33/81
Connections
Содержание Rexroth lndraControl VPB 40.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 6: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC IV 81 ...
Страница 20: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC 18 81 ...
Страница 48: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC 46 81 ...
Страница 72: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC 70 81 ...
Страница 78: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC 76 81 ...
Страница 80: ...Bosch Rexroth AG DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC 78 81 ...
Страница 83: ...Notes DOK SUPPL VPB 40 1 PR02 EN P Rexroth IndraControl VPB 40 1 Control Cabinet PC Bosch Rexroth AG 81 81 ...