Program Entry Guide

Содержание B8512G

Страница 1: ...Control Panel B9512G B8512G B9512G E B8512G E en Program Entry Guide ...

Страница 2: ......

Страница 3: ... 2 On Board Ethernet IP Communicator 31 3 2 1 IPv6 Mode 31 3 2 2 IPv4 DHCP AutoIP Enable 31 3 2 3 IPv4 Address 32 3 2 4 IPv4 Subnet Mask 32 3 2 5 IPv4 Default Gateway 32 3 2 6 IPv4 DNS Server IP Address 33 3 2 7 IPv6 DNS Server IP Address 33 3 2 8 UPnP Universal Plug and Play Enable 33 3 2 9 ARP Cache Timeout sec 34 3 2 10 Module Hostname 34 3 2 11 TCP UDP Port Number 34 3 2 12 TCP Keep Alive Time...

Страница 4: ...orts 52 3 9 4 Personal Emergency Reports 52 3 9 5 User Reports 53 3 9 6 Test Reports 54 3 9 7 Diagnostic Reports 54 3 9 8 Output Reports 55 3 9 9 Auto Function Reports 55 3 9 10 RPS Reports 56 3 9 11 Point Reports 56 3 9 12 User Change Reports 57 3 9 13 Access Reports 57 3 10 Communicator overview 58 3 10 1 Primary Destination Device 59 3 10 2 Backup Destination Device 60 3 10 3 RG Same Network Re...

Страница 5: ... Miscellaneous 74 3 15 1 Duress Type 74 3 15 2 Cancel Reports 75 3 15 3 Call for Service Text First Language 75 3 15 4 Call for Service Text Second Language 75 3 15 5 On Site Authorization for Firmware Update 76 3 15 6 Enclosure Tamper Enable 76 3 15 7 Fire Summary Sustain 77 3 15 8 Fire Supervision Event Type 77 3 15 9 Fire Trouble Resound 77 3 15 10 Fire Drill Duration 78 3 15 11 Early Ambush Ti...

Страница 6: ...ame Text Second Language 91 4 1 3 Area On 92 4 1 4 Account Number 92 4 1 5 Force Arm Bypass Max 93 4 1 6 Delay Restorals 93 4 1 7 Exit Tone 93 4 1 8 Exit Delay Time 94 4 1 9 Auto Watch 94 4 1 10 Restart Time 94 4 1 11 Duress Enable 96 4 1 12 Area Type 96 4 1 13 Two Man Rule 98 4 1 14 Early Ambush 99 4 1 15 Fire Time 99 4 1 16 Fire Pattern 100 4 1 17 Burg Time 100 4 1 18 Burg Pattern 101 4 1 19 Gas...

Страница 7: ...ration 114 5 1 13 Assign Door 114 5 1 14 Trouble Tone 115 5 1 15 Entry Tone 116 5 1 16 Exit Tone 116 5 1 17 Arm Area Warning Tone 116 5 1 18 Close Door Warning Tone 116 5 1 19 Idle Scroll Lock 117 5 1 20 Function Lock 117 5 1 21 Abort Display 117 5 1 22 Cancel Display 118 5 1 23 Nightlight Enable 118 5 1 24 Nightlight Brightness 118 5 1 25 Silence Keypress Tone 118 5 1 26 Show Date and Time 118 5 ...

Страница 8: ... 133 8 1 3 Reset Sensors 134 8 1 4 Fail to Close Part On Armed 134 8 1 5 Force Armed 135 8 1 6 Watch Mode 135 8 1 7 Area Armed 135 8 1 8 Area Off 135 8 1 9 Area Fault 136 8 1 10 Duress Output 136 8 1 11 Part On Fault 136 8 1 12 Silent Alarm 137 8 1 13 Gas Bell 137 8 2 Panel Wide Outputs 137 8 2 1 AC Failure 137 8 2 2 Battery Trouble 138 8 2 3 Phone Fail 138 8 2 4 Comm Fail 138 8 2 5 Log Full 138 8...

Страница 9: ...View Area Status 150 9 3 7 View Delete Event Memory 151 9 3 8 View Point Status 151 9 3 9 Walk Test all Non Fire Burg Points 151 9 3 10 Walk Test All Fire Points 151 9 3 11 Send Report Test Status 152 9 3 12 Door Control 152 9 3 13 Set Keypad Brightness Volume Keypress 152 9 3 14 Set Show Date and Time 152 9 3 15 Change Passcodes 153 9 3 16 Add Edit User 153 9 3 17 Delete User 153 9 3 18 Extend Cl...

Страница 10: ...3 9 4 17 Cycle Door 164 9 4 18 Un Lock door 164 9 4 19 Secure Door 164 9 4 20 Change Keypad Display 165 9 4 21 Change Date and Time 165 9 4 22 Change Passcodes 165 9 4 23 Add User Passcodes Card Level 165 9 4 24 Delete User Passcode Card Level 166 9 4 25 Extend Close 166 9 4 26 View Event Log 166 9 4 27 User Command 7 166 9 4 28 User Command 9 167 9 4 29 Bypass a Point 167 9 4 30 Unbypass a Point ...

Страница 11: ... Language 182 10 3 2 Point Profile Text Second Language 183 10 3 3 Point Response overview 183 10 3 4 Point Type 184 10 3 5 Point Response 184 10 3 6 Entry Delay 190 10 3 7 Entry Tone Off 191 10 3 8 Silent Bell 191 10 3 9 Ring Until Restored 192 10 3 10 Audible After Two Fails 192 10 3 11 Invisible Point 192 10 3 12 Buzz on Fault 193 10 3 13 Watch Point 193 10 3 14 Output Response Type 194 10 3 15...

Страница 12: ...ules 207 11 1 Open Close Windows 207 11 1 1 Opening window timeline 207 11 1 2 Opening_Closing windows table 208 11 1 3 Sunday through Saturday 209 11 1 4 Open Early Begin 209 11 1 5 Open Window Start 210 11 1 6 Open Window Stop 211 11 1 7 Close Early Begin 211 11 1 8 Close Window Start 212 11 1 9 Close Window Stop 212 11 1 10 Xept on Holiday 213 11 1 11 Holiday 213 11 1 12 Area 214 11 2 User grou...

Страница 13: ... 17 Cycle Door 221 11 5 18 Unlock Door 221 11 5 19 Lock Door 221 11 5 20 Secure Door 221 11 5 21 Access Ctrl Level 221 11 5 22 Access Granted Events 222 11 5 23 Access Denied Events 222 11 5 24 Answer RPS 222 11 5 25 Contact RPS 222 11 5 26 Contact RPS User Port 222 11 5 27 Send Status Report 222 11 5 28 Send Test Report 223 11 5 29 Send Test on Off Normal 224 11 5 30 Go to Area 224 11 5 31 Watch ...

Страница 14: ...ure Mode 234 12 1 27 Enclosure Tamper 234 12 2 Global Access settings 235 12 2 1 Card Type 235 13 Automation Remote App 236 13 1 Automation Device 236 13 2 Status Rate 236 13 3 Automation Passcode 236 13 4 Mode 1 Automation Ethernet Port Number 237 13 5 Remote App 237 13 6 Remote App Passcode 237 14 SDI2 modules 238 14 1 B208 Octo input 238 14 1 1 Enclosure Tamper 238 14 2 B299 POPEX 238 14 2 1 Mo...

Страница 15: ...cess Point Name APN 249 14 5 9 Network Access Point User Name 250 14 5 10 Network Access Point Password 250 14 6 B520 aux power supply 250 14 6 1 Module Enable 251 14 6 2 Module Enclosure Tamper 251 14 6 3 One or Two Batteries 251 14 7 Wireless Receiver 251 14 7 1 Wireless Module Type 252 14 7 2 Module Enclosure Tamper 253 14 7 3 System Repeater Supervision Time 253 14 7 4 Low Battery Resound 253 ...

Страница 16: ...ty Systems Inc 15 11 D8128 OctoPOPIT Module switch settings 264 15 12 D8129 Octo relay Module switch settings 265 15 13 D9127 POPITs Module switch settings 266 15 14 D9210 Access Interface Module switch settings 277 16 Configuring for Cellular Service 280 17 IP Address and Domain Name formats 282 ...

Страница 17: ...09 F 01U 303 998 1 Remote Programming Software Remote Programming Software RPS is an account management and control panel programming utility for Microsoft Windows operating systems Operators can perform remote programming account record storage remote control and diagnostics for specific control panels ...

Страница 18: ...parameter specifies whether or not this control panel requires SIA CP 01 False Alarm Reduction compliance If RPS receives programming data from the control panel that is not SIA CP 01 compliant the SIA CP 01 Compliance window opens Parameters that are out of compliance are listed Making the parameters SIA CP 01 compliant 1 Enter a value under the Desired Value column that is between the compliant ...

Страница 19: ...overs construction and performance requirements for control units and accessories for intrusion alarm systems including protected premises control units and accessories for local or signal receiving centre connections and signal receiving centre alarm receiving equipment including recording equipment The equipment is intended for use in premises safes and vaults Control panel programming requireme...

Страница 20: ...e to Fire Point Set Point Type Response Circuit Style Circuit Style to Single EOL 1KΩ or Single EOL 2KΩ Set Response to 3 Point Profile 4 Set Point Profile Text First Language to Fire Panel Alarm Set Point Type Response Circuit Style Point Type to Fire Point Set Point Type Response Circuit Style Circuit Style to Single EOL 1KΩ Single EOL 2KΩ or Dual EOL If you set Point Type Response Circuit Style...

Страница 21: ...Circuit Style to Single EOL 1KΩ or Single EOL 2KΩ set Response to 9 If you set Point Type Response Circuit Style Circuit Style to Dual EOL set Response to 2 Figure 2 2 Point Profiles Figure 2 3 Point Type Response and Circuit Style POINTS Point Assignments Set the POINTS Point Assignments Text and Profile parameters for on board points 1 2 and 3 as follows ...

Страница 22: ...panel silencing of fire alarm panel alarm trouble and supervisory events When control panels are configured as described below they automatically silence keypads connected to the control panel for fire trouble and supervisory events from the fire panel Notice Automatic silence not available for B3512 control panels Automatic silencing of fire alarm panel alarm trouble and supervisory events is not...

Страница 23: ...e 2017 03 09 F 01U 303 998 Figure 2 5 Custom Function 128 Figure 2 6 Area 1 selection OUTPUT PARAMETERS Panel Wide Outputs For virtual outputs Set Panel Wide Outputs Summary Fire to 9 Set Panel Wide Outputs Summary Fire Trouble to 10 Set Panel Wide Outputs Summary Supervisory Fire to 19 ...

Страница 24: ...onfigure Point Profile 20 as shown below It is important to configure the parameters in order Point Profile 20 Set Point Profile Text First Language to CF Silence Set Point Type Response Circuit Style Point Type to Custom Function Leave Point Type Response Circuit Style Circuit Style at the default Single EOL 1KΩ Leave Point Type Response Circuit Style Response at the default 7 ...

Страница 25: ...and 19 as follows Point 9 Set Point Assignments Source to Ouput Set Point Assignments Text to Fire Alarm Active Set Point Assignments Profile to 20 CF Silence Point 10 Set Point Assignments Source to Ouput Set Point Assignments Text to Fire Trouble Active Set Point Assignments Profile to 20 CF Silence Point 19 Set Point Assignments Source to Ouput Set Point Assignments Text to Fire Supervisory Act...

Страница 26: ... on site prior to establishing the phone call Refer to the control panel Installation Guide for instructions on entering service mode Service Mode is not required for other RPS connection mechanisms When sending the RPS account to the control panel the control panel logs and locally indicates a Programming Active trouble and reports Panel off line to the central station receiver When RPS disconnec...

Страница 27: ...essories for Fire Alarm Systems UL 864 you must limit certain programming features or options to specific values RPS Menu Location Compliance Settings UL864 Fire Application 2 4 Supervision configuration Optimizing data used for supervision Installation Type Commercial Burg UL1610 Commercial Burg ULC S304 High Supervision Hourly Medium Security or Household Fire Daily Supervision Required Supervis...

Страница 28: ...or Commercial Fire Systems To comply with UL 864 requirements for commercial fire systems enter a valid phone number in this parameter Configuring Phone Destinations for Call Waiting Dialing a call waiting sequence on a non call waiting line prevents the system from successfully sending reports to the central station receiver If you configure a Phone Destination with a phone number that includes a...

Страница 29: ... event and initiate a trouble tone if the Buzz on Fail page 30 and Trouble Tone page 115 parameters are set to Yes If the Alarm on Fail page 29 parameter is set to Yes keypads display an alarm event and sound the alarm tone When the control panel detects a normal phone line fault is cleared for the number of seconds set at this parameter it creates a phone line restoral event The control panel sen...

Страница 30: ...Buzz On Fail 3 1 7 Two Phone Lines Default No Selections Yes two B430 Plug in Telephone Communicator modules are installed No only one or no B430 Plug in Telephone Communicator modules are installed This parameter enables the dual phone line feature To supervise and send reports over two separate phone lines set this parameter to Yes and install two B430 Plug in Telephone Communicator modules The ...

Страница 31: ...N Compatibility parameter to Australia or New Zealand you must set Panel Wide Parameters RPS Parameters Answer Armed and Answer Disarmed to 0 disabled RPS Menu Location Panel Wide Parameters Phone and Phone Parameters PSTN Compatibility 3 2 On Board Ethernet IP Communicator 3 2 1 IPv6 Mode Default No Selections Yes Enable IPv6 No Disable IPv6 Use IPv4 mode This parameter configures IP communicatio...

Страница 32: ...er is set to No enter the IPv4 address here Further Information IP Address and Domain Name formats page 282 RPS Menu Location Panel Wide Parameters Onboard Ethernet Communicator IPv4 address 3 2 4 IPv4 Subnet Mask Default 255 255 255 0 Selections 0 0 0 0 to 255 255 255 255 This parameter sets the address for the IPv4 Subnet Mask If the IPv4 DHCP Auto IP Enable parameter is set to Yes this paramete...

Страница 33: ...ations Panel Wide Parameters Onboard Ethernet Communicator IPv4 DNS server IP address 3 2 7 IPv6 DNS Server IP Address Default Selections 0000 0000 0000 0000 0000 0000 0000 0000 to FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF This parameter configures the IPv6 DNS server address in Static IP mode A Domain Name Server DNS converts internet domain names or hostnames to their corresponding IP addresses In...

Страница 34: ...his parameter blank to use factory default hostname The factory default hostname begins with the letter B followed by the last six digits of the modules MAC address Use RPS diagnostics or installer keypad diagnostics to view the hostname Use the hostname on a local network using DHCP To use the hostname externally you must enter the hostname in the DNS server You can use the hostname to connect to...

Страница 35: ...nd the network configuration settings Further information IP Address and Domain Name formats page 282 RPS Menu Locations Panel Wide Parameters Onboard Ethernet Communicator IPv4 Test Address 3 2 14 IPv6 Test Address Default 2001 4860 4860 8888 Selections IPv6 address or Domain Name The default test address works for most networks This parameter is only available when IPv6 Mode is set to Yes The co...

Страница 36: ... DNS server IP address 3 3 Cellular Plug in Module 3 3 1 Inbound SMS Notice Important configuration information for cellular communication Refer to Configuring for Cellular Service page 280 for an overview and configuration information Default Yes Selections Yes Enabled No Disabled This parameter enables an RPS user to start a control panel initiated download with an SMS message RPS Menu Location ...

Страница 37: ...ing Delay for Low Signal Strength sec Notice Important configuration information for cellular communication Refer to Configuring for Cellular Service page 280 for an overview and configuration information Default 0 Selections 0 3600 seconds 0 Disabled 1 to 3600 seconds of delay before Cellular Low Signal event Notice UL Requirement To meet UL requirements the entry for this parameter should not ex...

Страница 38: ...e contro panel creates a No IP Address restoral event when the cellular plug in module successfully registers with one or more towers and receives an IP address Notice When one or more towers are available 60 second delay for No IP Address event If the cellular plug in module successfully registers with one or more towers but does not receive an IP address within 60 seconds the control panel creat...

Страница 39: ...ion Default Blank Selections 0 30 ASCII characters This parameter specifies the user name for the Network Access Point Enter up to 30 alphanumeric characters The field is case sensitive RPS Menu Location Panel Wide Parameters Cellular Plug in Module Network Access Point User Name 3 3 9 Network Access Point Password Notice Important configuration information for cellular communication Refer to Conf...

Страница 40: ...ions you need to visit https installerservices boschsecurity com to sign up for Bosch Installer Services RPS Menu Location Panel Wide Parameters Cloud Remote Connect Cloud Remote Connect via Ethernet 3 4 2 Cloud Remote Connect Cellular Default Disable Selections Enable Disable Use this parameter to enable the control panel to use the Bosch Cloud based Service Remote Connect for communication via a...

Страница 41: ... the URL or IP address for the Bosch IP camera The control panel or RSC application uses the URL or IP address to communicate with the camera over a network RPS Menu Location Panel Wide Parameters IP Cameras URL or IP Address 3 6 Bosch Connected Cameras Products B9512G and B8512G with on board IP communicator All Bosch IP cameras Applications Bosch IP cameras are best for small commercial and resi...

Страница 42: ...ervision This parameter sets the length of time the control panel monitors a missing Bosch IP camera before reporting the camera as missing RPS Menu Location Panel Wide Parameters IP Cameras Bosch Connected Camera Supervision Period 3 7 Live video Products B9512G and B8512G with on board IP communicator All Bosch IP cameras RSC Remote Security Control Applications Live video is best for small comm...

Страница 43: ...d the RSC Set to Yes if the live viewer requires HTTPS Notice When using HTTPS set Panel Wide Parameters IP Cameras Live Video Port to 443 The B9512G supports Cameras 1 to 16 The B8512G supports Cameras 1 to 8 RPS Menu Location Panel Wide Parameters IP Cameras Live Video Use HTTPS 3 7 3 User Name Default live Selection Enter up to 32 characters This parameter specifies the user name that the RSC a...

Страница 44: ...xx Point xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx Route Group 2 Primary Destination Device Backup Destination Device Test xxxxxx xxxxxx Per Emer xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx Fire xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx Gas xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx Burglar xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx User xxxxxx x...

Страница 45: ...age 239 or here B450 cellular page 246 and here Enhanced Communication page 62 Route Group priority Route Group 1 has the highest priority Route Group 4 has the lowest priority When there are reports in more than one Report Group to be sent at the same time the control panel sends the report in the highest priority Route Group first For example if there are reports in Route Group 2 and Route Group...

Страница 46: ...Interference and Restore Equipment Fail and Restore Personal Notification Communication Trouble and Restore RPS Reports Event Log Threshold Event Log Overflow Parameters Changed RPS Access OK RPS Access Fail Remote Reset Program Access OK Program Access Fail Point Reports Service Start Service End Fire Walk Start Fire Walk End Walk Test Start Walk Test End Extra Point RF Low Battery RF Battery Res...

Страница 47: ...t one of the reports in the category is configured individually Notice Configuration for individual reports lost on change from Custom to Yes or No When Custom appears for a category of reports it indicates that not all of the reports are set the same all Yes or all No The reports have been set individually If you change the reports for a category from Custom to Yes or No the configuration for the...

Страница 48: ...tegory Alarm Report Burg Restore After Trouble Duress Missing Alarm User Code Tamper Trouble Report Missing Trouble Non Fire Supervision Point Bus Fail Point Bus Restoral Non Fire Cancel Alarm Restore Supervision Missing Unverified Event To individually assign reports from the Burglar category to a Route Group click Burglar Reports page 52 in the menu tree Personal Emergency Reports Reports in the...

Страница 49: ...lick User Reports page 53 in the menu tree Test Reports Reports in the Test category Status Report Test Report To individually assign reports from the Test category to a Route Group click Test Reports page 54 in the menu tree Diagnostic Reports Reports in the Diagnostic category SDI2 Device Failure SDI2 Device Restoral Watchdog Reset Parameter Checksum Fail Reboot Phone Line Fail Phone Line Restor...

Страница 50: ...nction category to a Route Group click Auto Function Reports page 55 in the menu tree RPS Reports Reports in the RPS category Event Log Threshold Event Log Overflow Parameters Changed RPS Access OK RPS Access Fail Remote Reset Program Access OK Program Access Fail To individually assign reports from the RPS category to a Route Group click RPS Reports page 56 in the menu tree Point Reports Reports ...

Страница 51: ...Yes Yes Yes No Fire Trouble Yes Yes Yes No Fire Supervision Yes Yes Yes No Fire Restoral after Trouble Yes Yes Yes No Fire Cancel Yes Yes Yes No Fire Supervision Missing Yes Yes Yes No Fire Supervision Restoral Yes Yes Yes No Selections Yes assign this report to the Route Group No do not assign this report to the Route Group RPS Menu Location Panel Wide Parameters Report Routing Fire Reports 3 9 2...

Страница 52: ...store after Alarm Yes Yes Yes No Duress Yes Yes Yes Yes Missing Alarm Yes Yes Yes No User Code Tamper Yes Yes Yes No Trouble Report Yes Yes Yes No Missing Trouble Yes Yes Yes No Non Fire Supervision Yes Yes Yes No Point Bus Fail Yes Yes Yes No Point Bus Restoral Yes Yes Yes No Non Fire Cancel Yes Yes Yes No Alarm Restore Yes Yes Yes No Supervision Missing Yes Yes Yes No Unverified Event Yes Yes Ye...

Страница 53: ...ters Report Routing Personal Emergency Reports 3 9 5 User Reports Default User Reports Route Group 1 Route Group 2 Route Group 3 Route Group 4 Forced Point Yes Yes Yes No Point Opening Yes Yes Yes No Point Closing Yes Yes Yes No Was Forced Armed Yes Yes Yes No Fail to Open Yes Yes Yes No Fail to Close Yes Yes Yes No Extent Close Time Yes Yes Yes No Opening Report No No No No Forced Close No No No ...

Страница 54: ... 1 Route Group 2 Route Group 3 Route Group 4 SDI2 Device Failure Yes Yes Yes No SDI2 Device Restoral Yes Yes Yes No Watchdog Reset Yes Yes Yes No Parameter Checksum Fail Yes Yes Yes No Reboot Yes Yes Yes No Phone Line Fail Yes Yes Yes No Phone Line Fail Restoral Yes Yes Yes No AC Failure Yes Yes Yes No AC Restoral Yes Yes Yes No Battery Missing Yes Yes Yes No Battery Low Yes Yes Yes No Battery Res...

Страница 55: ...assign this report to the Route Group Notice Enable Route Comm Fail and Rout Comm Restore reports in only one route group RPS Menu Location Panel Wide Parameters Report Routing Diagnostic Reports 3 9 8 Output Reports Default Output Reports Route Group 1 Route Group 2 Route Group 3 Route Group 4 Sensor Reset Yes Yes Yes No Output Set Yes Yes Yes No Output Reset Yes Yes Yes No Send Output Name Text ...

Страница 56: ...Event Log Threshold Yes Yes Yes No Event Log Overflow Yes Yes Yes No Parameters Changed Yes Yes Yes No RPS Access OK Yes Yes Yes No RPS Access Fail No No No No Remote Reset Yes Yes Yes No Program Access OK Yes Yes Yes No Program Access Fail Yes Yes Yes No Selections Yes assign this report to the Route Group No do not assign this report to the Route Group RPS Menu Location Panel Wide Parameters Rep...

Страница 57: ...eters Report Routing Point Reports 3 9 12 User Change Reports Default User Change Reports Route Group 1 Route Group 2 Route Group 3 Route Group 4 Date Changed Yes Yes Yes Yes Time Changed Yes Yes Yes No Delete User Yes Yes Yes No User Code Change Yes Yes Yes No Area Watch Yes Yes Yes No Keyfob Assigned Yes Yes Yes No Keyfob Removed Yes Yes Yes No Change Level Yes Yes Yes Yes Selections Yes assign ...

Страница 58: ... report the Backup Destination Device destination device is used The control panel makes up to ten communication attempts using the primary and backup destination devices to send reports in a Route Group The control panel alternates between the primary and backup destination devices as shown below If unsuccessful after 10 attempts it creates a Comm Fail Event 1 Primary Destination Device 2 Primary...

Страница 59: ...polls are not received after the configured number of retries If all attempts to both the primary destination device and the backup destination device fail a COMM FAIL RG event is generated COMM RESTORE events are not generated for COMM FAIL events Notice CAN ULC S304 requirement do not clear pending reports When CAN ULC S304 is set to YES the control panel does not clear pending reports before cr...

Страница 60: ...nation 3 Onboard IP Destination 4 Plug in Cellular Destination 1 Plug in Cellular Destination 2 Plug in Cellular Destination 3 Plug in Cellular Destination 4 Plug in Phone Destination 1 Plug in Phone Destination 2 Plug in Phone Destination 3 Plug in Phone Destination 4 SDI2 address 1 Destination 1 SDI2 address 1 Destination 2 SDI2 address 1 Destination 3 SDI2 address 1 Destination 4 SDI2 address 2...

Страница 61: ...s to the receiver use different IP Addresses or Port Numbers This parameter also enables the backup destination poll time to change to the primary poll time in the event of a Communication Trouble event Set this parameter to Yes when the following applies Both primary and backup devices use enhanced communication via an IP destination on board or SDI2 Both primary and backup destinations are the s...

Страница 62: ... Selections Contact ID Use this format when the central station receiver only supports contact ID Modem4 The control panel sends expanded Modem4 Communication Format reports to the central station receiver This parameter sets the central station receiver format for transmission of reports When using telephone or network reporting event reports can be routed to a central station receiver using eith...

Страница 63: ...l RPS shows a warning message and asks if you wish to continue If you click No RPS forces you to enter unique values for the Port Number and IP Address fields If you click Yes RPS allows you to enter duplicate values RPS Menu Location Panel Wide Parameters Enhanced Communications Port Number Destination 1 to 4 3 11 4 Receiver Supervision Time Default 4 Hours Medium Security Selections 200 Seconds ...

Страница 64: ...s These parameters can only be edited when the Receiver Supervision Time parameter is set to Custom The first time Custom is selected the default value for the Poll Rate ACK Wait and Retry Count parameters is zero Once these parameters are changed from the default RPS retains the values even if the Receiver Supervision Time parameter is changed from the Custom selection Each time Custom is reselec...

Страница 65: ...l event The control panel continues to re send the heartbeat poll every 10 seconds until it receives an acknowledgement even after declaring a Comm Fail When the control panel receives acknowledgement from the central station the control panel returns to the normal poll rate If more than one network destination is used the control panel handles them on a successive basis For example if acknowledge...

Страница 66: ... Count parameters are reset to the saved values This parameter determines how long the control panel will wait for an acknowledgement from the central station after a heartbeat poll or an actual event has been transmitted Actual non heartbeat events will wait the set value or a maximum of 15 seconds before the next communication attempt is made RPS Menu Location Panel Wide Parameters Enhanced Comm...

Страница 67: ...characters represented by an ID 01 to 100 This parameter allows each receiver destination to be configured with a unique AES encryption key The AES Encryption Key is based on AES Key Size page 67 For the encryption key configuration only Key ID Name is displayed By default RPS sets the AES Key string to Default RPS validates if two or more network destinations have the same network address If yes ...

Страница 68: ...er passcode Enter the installer passcode and press ENTER RPS Menu Location Panel Wide Parameters SDI RPS Enhanced Communication Answer RPS Over Network 3 12 3 RPS Address Verification Default No Selections Yes this setting verifies that the incoming RPS IP address matches the address entered in RPS Network Address page 68 No this setting allows RPS to connect to the control panel from any IP addre...

Страница 69: ...ter 12 Hours re send AC Fail report to central station after 12 hours of non restoral This parameter sets the time interval that must pass without the AC failure event being restored before the control panel re sends the AC Failure report to the central station RPS Menu Location Panel Wide Parameters Power Supervision Resend AC Fail 3 13 3 AC Fail Display Default 60 Selections 10 to 300 seconds in...

Страница 70: ...es initiate panel wide trouble tone at all keypads No do not Initiate panel wide trouble tone at keypads This parameter initiates a panel wide trouble tone at keypads when the AC fails or the battery is low or missing Notice UL 864 requirement for commercial fire To comply with UL864 requirements for commercial fire systems set this parameter to Yes This parameter does not prevent AC fail or low b...

Страница 71: ...ions The RPS passcode defaults to 999999 in the control panel In an RPS default account the passcode is also 999999 A default RPS account can connect to a default control panel without modifying the RPS passcode in either the RPS account or in the control panel RPS Menu Location Panel Wide Parameters RPS Parameters RPS Passcode 3 14 2 Log Full Default 0 Selections 0 to 99 0 zero This setting disab...

Страница 72: ...g up and dialing the RPS phone number to call RPS at the central station prior to allowing any upload or download RPS Menu Location Panel Wide Parameters RPS Parameters RPS Call Back 3 14 5 RPS Line Monitor Default Yes Selections Yes this setting allows the control panel to communicate with RPS after the answering machine has answered the phone No use this setting if the control panel is not shari...

Страница 73: ...er Armed and the Answer Disarmed parameter to 0 disabled RPS Menu Location Panel Wide Parameters RPS Parameters Answer Armed 3 14 7 Answer Disarmed Default 7 Selections 0 to 15 rings 0 zero this setting disables answering the phone 1 to 15 use this setting to have the control panel answer the phone after the specified number of rings when all areas are All On Notice RPS considers Part On as a disa...

Страница 74: ...to generate an alarm For example If the passcode is 6123 6124 activates a duress alarm If the last digit of the passcode is 0 a duress alarm occurs when the user enters 1 as the last digit of the passcode If the last digit of the passcode is 9 a duress alarm occurs when the user enters 0 as the last digit of the passcode 2 increase the last digit by 2 to generate an alarm For example If the last d...

Страница 75: ...r allows the user to customize the Call for Service message that is displayed at keypads Enter up to 32 characters of text numbers and symbols Keypads display the first 20 characters If more than 20 characters are used the text scrolls across the display one time To scroll the text again press ESC Spaces before after and within a string of text are treated as text and are included in the 32 charac...

Страница 76: ... Firmware Update Wizard through the IP connection on board ethernet connection or a B42x module provides for easy feature enhancements without replacing ROM chips Remote firmware updates must be authorized on site for UL listed systems RPS Menu Location Panel Wide Parameters Miscellaneous On Site Authorization for Firmware Update Further information Firmware Update page 175 3 15 6 Enclosure Tamper...

Страница 77: ...mary Sustain 3 15 8 Fire Supervision Event Type Default 2 Fire Supervision Restoral Selections 0 Fire Trouble Restoral the control panel transmits a FIRE TROUBLE RESTORE when a Fire Supervision point restores to normal 1 Fire Alarm Restoral the control panel transmits a FIRE ALARM RESTORE when a Fire Supervision point restores to normal 2 Fire Supervision Restoral the control panel transmits a FIR...

Страница 78: ...12 Second Ambush Code Default Unique Selections Unique the passcode used to end the Early Ambush Time page 78 must be different from the passcode used to disarm the area Any the Early Ambush Time can be stopped using a different passcode or the same passcode used to disarm the area This parameter determines whether the same passcode can be used to start and end the Early Ambush page 99 process RPS...

Страница 79: ...a passcode 1 Click the appropriate cell in the User Passcode column to select the passcode 2 Press the Backspace key on your keyboard to clear the cell 3 Enter the new passcode There are two option buttons that control how this parameter handles passcode entries Save corrected passcodes This option is selected by default All passcodes marked as duplicate or unusable must be fixed before you click ...

Страница 80: ...e you enter resembles another existing passcode the existing passcode appears in the Existing Similar Passcodes field Duplicate Passcodes If you enter a passcode that matches an existing passcode the existing passcodes appear in the Duplicate Duress Passcodes field Passcode matches are based on duplicate entries with the length set to the lowest value that complies with SIA CP 01 3 For example if ...

Страница 81: ...default to No RPS Menu Location Panel Wide Parameters Miscellaneous Remote Warning 3 15 17 Crystal Time Adjust Default No Selections Yes the control panel uses the on board crystal frequency to regulate its clock time No the control panel uses traditional AC frequency to regulate its clock time This parameter determines how the control panel regulates its clock time RPS Menu Location Panel Wide Pa...

Страница 82: ...on Panel Wide Parameters Miscellaneous Daylight Saving Time 3 15 21 Date Format Default mm dd yy Selections mm dd yy dd mm yy yy mm dd This parameter determines how the date is displayed Choose how the month day and year are delimited separated in the Date Delimiter parameter RPS Menu Location Panel Wide Parameters Miscellaneous Date Format 3 15 22 Date Delimiter Default forward slash Selections f...

Страница 83: ...0 Central America UTC 06 00 Central Time US Canada UTC 06 00 Guadalajara Mexico City Monterrey UTC 06 00 Saskatchewan UTC 05 00 Bogota Lima Quito UTC 05 00 Eastern Time US Canada UTC 05 00 Indiana East UTC 04 30 Caracas UTC 04 00 Asuncion UTC 04 00 Atlantic Time Canada UTC 04 00 Georgetown La Paz San Juan UTC 04 00 Manaus UTC 04 00 Santiago UTC 03 30 Newfoundland UTC 03 00 Brasilia UTC 03 00 Bueno...

Страница 84: ... UTC 05 00 Tashkent UTC 05 30 Chennai Kolkata Mumbai New Delhi UTC 05 30 Sri Jayawardenepura UTC 05 45 Kathmandu UTC 06 00 Almaty Novosibirsk UTC 06 00 Astana Dhaka UTC 06 30 Yangon Rangoon UTC 07 00 Bangkok Hanoi Jakarta UTC 07 00 Krasnoyarsk UTC 08 00 Beijing Chongqing Hong Kong Urumqi UTC 08 00 Irkutsk Ulaan Bataar UTC 08 00 Kuala Lumpur Singapore UTC 08 00 Perth UTC 08 00 Taipei UTC 09 00 Osak...

Страница 85: ...s Disable Enable This parameter enables the control panel to detect ground faults on Terminals 1 to 9 and 11 to 30 Notice UL 864 Commercial Fire Systems requirement To comply with UL 864 requirements for Commercial Fire Systems set this parameter to Enable When circuit impedance to earth ground is less than a predefined value the control panel sends a report to the central station receiver The con...

Страница 86: ...ndow Selections 1 first language 2 second language This selection determines the language that the personal notification message is sent in First and Second languages are programmed during panel account setup in the New Panel Data window Supported languages include English Spanish French and Portuguese RPS Menu Location Panel Wide Parameters Personal Notification Personal Notifications Destination...

Страница 87: ...erbatim from an internet email provider Notice If the destination is neither a valid phone or valid email no message will be sent and an SMS send error will be logged Notice You are not required to set the Primary or Backup Destination Device parameters to Cellular IP for Personal Notification by SMS to work RPS Menu Location Panel Wide Parameters Personal Notification Personal Notifications Repor...

Страница 88: ...ch emails are coming from the control panel example panelacctstore52 3 Enter the address associated with the SMTP email server you chose in the Email Server Name Address parameter 4 Enter the user name you specified when registering for this account in the Authentication User Name parameter 5 Enter the password you specified when registering for this account in the Authentication Password paramete...

Страница 89: ...izon outgoing verizon net Virgin smtp virgin net Wanadoo smtp wanadoo fr Yahoo smtp mail yahoo com Further information IP Address and Domain Name formats page 282 RPS Menu Location Panel Wide Parameters Personal Notification Email Server Configuration Email Server Name Address 3 19 2 Email server port number Default 25 Selections 1 65535 This parameter specifies the port number for the email serve...

Страница 90: ...cure Sockets Layer SSL Transport Layer Security TLS RPS Menu Location Panel Wide Parameters Personal Notification Email Server Configuration Email Server Authentication Encryption 3 19 4 Authentication user name Default Blank Selections Blank 1 to 255 characters This parameter specifies the user name for the email account that is set up to receive messages from the SMTP server sent by the control ...

Страница 91: ...configured with the garage and house as separate areas In each of the examples above all of the areas are under the sole responsibility of a single owner In multi area systems the bell or siren and control panel must be in one of the protected areas The bell or siren must be located where it can be heard by users who turn areas on and off arm and disarm The B9512G supports up to 32 areas The B8512...

Страница 92: ...ll user authority in this area is turned off while the area is disabled RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Area On 4 1 4 Account Number Default 0000 Selections 4 or 10 digit numbers 0 9 B F This parameter determines the account number reported for this area An account number must be assigned to each active area If 5 or more digits are used in the account...

Страница 93: ...arameters Open Close Options Force Arm Bypass Max 4 1 6 Delay Restorals Default No Delay Selections No Delay Point restoral events are logged and reported when the point physically restores Delay Until Bell Expires Point restoral events are not logged or reported until the point has physically restored and the bell silenced or bell time expires Use this parameter to delay restoral reports Notice U...

Страница 94: ...lly turns Watch Mode on when the area is turned off disarmed When an area is off disarmed Watch Mode is on and points configured as Watch Point page 193s are faulted a watch tone sounds at keypads assigned to the area When the area is Part On only interior points configured as Watch Points sound the watch tone when they are faulted Perimeter points report faults as alarms or troubles If this Auto ...

Страница 95: ...nt set Point Type to Fire and Alarm Verify and Resettable to Yes When an alarm verification point is faulted the control panel automatically removes power to all resettable points connected to the areas Reset Sensors output Power is removed for 4 5 seconds When power is reapplied the control panel ignores alarms from the resettable points for the amount of time programmed in Restart Time After Res...

Страница 96: ...y arming or are All On Delay A Check Area message displays if the Associate areas have not yet been armed EXCEPTION RPS allows Master areas to be armed without all Associate areas being in the armed state A Master area can be disarmed regardless of the armed state of the other areas in the account Multiple Master areas can be programmed in a single account Notice Keypad Scope affects master arming...

Страница 97: ...unt assignments The shares area does not begin to arm until all Associates finish arming Shared Area Characteristic Description Arming a Shared Area Requires all Associate areas to be armed As soon as the last Associate area is armed the Shared area begins its arming sequence automatically Shared areas cannot be armed by passcode keyswitch or RPS To allow faulted points to be displayed at associat...

Страница 98: ... exit delay will restart and allow a user to walk to an Associate area and disarm If the card reader assigned to the Shared area includes any Associate area in the D KP Scope in the ACCESS CONTROL section both the Associate area and Shared area will disarm when the card is presented Closing Reports for Shared Areas If closing reports for Shared areas are required Passcodes must also have a valid a...

Страница 99: ...14 Early Ambush Default No Selections Yes two valid passcodes are required to disarm the area within the time limit set in the Early Ambush Time page 78 parameter No one passcode with a valid authority level can disarm the area This parameter requires two valid passcodes to disarm the area within the time limit set in the Early Ambush Time page 78 parameter Notice To comply with SIA CP 01 False Al...

Страница 100: ...an even tempo 0 5 seconds on and 0 5 seconds off California Standard 10 seconds audible 5 seconds silent 10 seconds audible 5 seconds silent This sequence repeats until bell time expires Temporal Code 3 0 5 seconds On 0 5 seconds Off 0 5 seconds On 0 5 seconds Off 0 5 seconds On 1 5 seconds Off pattern repeats This sequence repeats for a minimum of 3 minutes with 10 timing tolerance 1999 NFPA stan...

Страница 101: ...uence repeats for a minimum of 3 minutes with 10 timing tolerance 1999 NFPA standards allow automatic silencing as permitted by the Authority Having Jurisdiction AHJ and carry a minimum ring time of 5 minutes Select the bell pattern this area uses to signal an alarm on a non fire point RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Burg Pattern 4 1 19 Gas Pattern De...

Страница 102: ...utput programmed at Alarm Bell page 133 after the closing report has been confirmed or the exit delay time has expired When more than one area is armed at the same time for example ARM ALL AREAS Function is used the bell sounds for two seconds with a two second pause between each bell activation if all areas have the same exit delay time programmed Otherwise the bell test occurs as each area is ar...

Страница 103: ...g and closing window times Note Account numbers are sent over the network to the central station receiver RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Account O C 4 1 23 Area O C Default Yes Selections Yes include the area number and generate opening and closing reports for this area when it is armed No do not include the area number or generate opening and closin...

Страница 104: ...ea automatically arms All On Delay at the end of the close window When the area automatically arms the control panel sends a closing report if area and or account reports are programmed to do so No do not automatically arm the area at the end of the close window With this parameter the control panel can automatically arm the area All On Delay at the end of the closing window regardless of the prev...

Страница 105: ...t be greater than or equal to the Latest Close Time setting For example if the Latest Close Time parameter is set to 17 30 the Close Window Start parameter cannot be set to 17 30 or higher RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Latest Close Time 4 1 29 Restricted O C Default No Selections Yes restrict opening and closing reports for this area Area O C page 1...

Страница 106: ...Exit Delay Restart No do not restart Exit Delay The Exit Delay Restart feature automatically restarts exit delay when an end user reenters the premises before exit delay expires For example a home owner turns on arms their system leaves and closes the door then realizes they forgot to pick up the car keys When they open the door to retrieve their keys the control panel restarts exit delay giving t...

Страница 107: ...s parameter enables the alarm bell to pulse on and off every two seconds for the remaining 10 seconds of Exit Delay Notice To comply with SIA CP 01 False Alarm Reduction set this parameter to Yes Refer to SIA CP 01 Verification for more information RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Exit Delay Warning 4 1 34 Entry Delay Warning Default No Selections Yes ...

Страница 108: ...dow is running simultaneously with the Area Re arm timer and a user uses the Extend Close time from a system keypad the control panel extends only the Closing Window not the Area Re Arm Time RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Area Re Arm Time 4 2 Area Arming Text The B9512G supports up to 32 areas The B8512G supports up to 8 areas 4 2 1 Area name text De...

Страница 109: ...ea Arming Text Area is On Text 4 2 4 Area is not Ready text Default Blank Selection Enter up to 32 characters This parameter displays the text to display at the keypad for each area as required Notice When using a D1255F D1256F or D1257F keypad program this parameter as Fire System RPS Menu Location Area Wide Parameters Area Bell Parameters Open Close Options Area Arming Text Area Not Ready Text 4...

Страница 110: ...d Name 5 1 2 Keypad Name Second Language Default blank Selections Up to 32 characters This parameter sets what is displayed at keypads This is for informational purposes only Enter up to 32 characters of text numbers and symbols to describe the keypad Keypads display the first 20 characters If more than 20 characters are used the keypad name text scrolls across the display one time To scroll the t...

Страница 111: ...d Language ignore User language This parameter sets the language that is displayed at the keypad RPS Menu Location Keypads Keypad Assignments Keypad Language 5 1 6 Scope Default Address 1 Panel Wide All other Addresses Area Wide Selections Area Wide An area keypad is restricted to the viewing information and arming disarming functions for the area it is assigned to Account Wide An account keypad c...

Страница 112: ...ll KP addresses Selections Yes change the armed state of the areas within the scope of this keypad If the areas in the scope are already at the intended armed state they remain in that state No view areas within the programmed scope but only arm or disarm the area programmed in Area Assignment when a passcode is entered This parameter determines whether this keypad follows Scope or whether it only...

Страница 113: ...an use the Passcode Enter Function Cycle Door and the Enter Key Output for a low level access control strike on a door It does not shunt a point RPS Menu Location Keypads Keypad Assignments Enter Key Output Further information Passcode Enter Function page 113 5 1 10 Passcode Enter Function Default Arm Disarm for all KP addresses Selections Arm Disarm Passcode ENTER starts All On Delay arming for a...

Страница 114: ...ain access Before setting this parameter to YES first Assign Door page 114 or Keypad Type page 110 If the keypad is a B94X Touch Screen and the Assign Door prompt is set to No Door then the keypad reader is used for Dual Authentication If the keypad is a B94X Touch Screen and the Assign Door prompt is set to Door then the keypad reader is disabled and the door reader is used for Dual Authenticatio...

Страница 115: ...sing the DOOR CONTROL function Any door that is active can be controlled by a user who has the door control authority enabled at a keypad with the doors area assigned in the ACCESS CONTROL section within its scope Notice During the ADD USER mode token cards door control requests and RTE REX do not function If there is heavy activity for this door set the door mode into an unlocked state before add...

Страница 116: ...es not sound exit tones This parameter determines whether this keypad or any keypad with the same address setting sounds the exit delay tone during the delay arming of an area Any keypad that has a scope to arm this area can initiate the exit tone sequence This parameter allows you to manage the tone by keypad Exit tone can also be turned off when programming your Exit Tone in Area Parameters Assi...

Страница 117: ...key requires a passcode before proceeding No pressing the Bypass Menu or Shortcuts key does not require a passcode until a function requiring one is selected This parameter determines if the Function Lock requires a passcode when pressed to access the functions The user is prompted to enter a passcode after pressing the Bypass Menu or Shortcuts key on the keypad The items programmed in the functio...

Страница 118: ...o enable the nightlight feature on the keypad When set to Yes The display backlight and key backlight B920 B930 shall remain illuminated at the minimum level when the keypad is Idle RPS Menu Location Keypads Keypad Assignments Nightlight Enable 5 1 24 Nightlight Brightness Default 2 Selections 0 to 6 0 Nightlight off 1 to 6 increases or decreases nightlight brightness The higher the number the bri...

Страница 119: ...s Keypad Assignments Keypad Volume 5 1 28 Keypad Brightness Default 6 Selections 0 to 6 0 Lowest setting 1 to 6 increases or decreases keypad display brightness The higher the number the brighter the display This parameter sets the brightness for the LED display on the keypad Keypad brightness can also be set at the keypad RPS Menu Location Keypads Keypad Assignments Keypad Brightness 5 1 29 Disab...

Страница 120: ...nel Info tab of the Panel Data dialog box Event Memory allows the user to quickly access and view Event Memory This parameter sets which feature shows in the upper left corner of a B94x keypad display This parameter applies to B94x Touch Screen keypads only RPS Menu Location Keypads SDI2 Keypad Assignments Feature Button Option 5 1 33 Supervision Default Yes Selections Yes only one keypad can be i...

Страница 121: ...efault Yes Selections Yes entering a user passcode followed by the Esc key performs the legacy D125x sequence If bells are sounding alarms the alarms are acknowledged If no bells are sounding and either silence or clear operations are allowed the clear display task is executed No pressing the Esc key erases the last digit and if no digits are entered the task is exited Notice This option is only a...

Страница 122: ...ds Global Keypad Settings A Key Response 5 2 2 A Key Custom Function Default Disabled Selections B9512G Disabled Function 128 to Function 159 B8512G Disabled Function 128 to Function 135 This parameter specifies the custom function that is run when an A key and 1 key are held together for 2 sec and the A key is configured to run a custom function If the custom function number is disabled and the A...

Страница 123: ...This parameter specifies the custom function that is run when an B key is held and the B key is configured to run a custom function If the custom function number is disabled and the B key is configured to run a custom function holding the B key generates an invalid key press response The number of custom functions supported varies based on the control panel type Select the CF that corresponds to t...

Страница 124: ...igured to run a custom function holding the C key generates an invalid key press response The number of custom functions supported varies based on the control panel type Select the CF that corresponds to the custom function programmed in Custom Functions Notice The C Key Custom Function option is not available with B942 touch screen keypads RPS Menu Location Keypads Global Keypad Settings C Key Cu...

Страница 125: ...s Comm Trouble Sound Options 5 3 Global Wireless Keyfob 5 3 1 Keyfob Function A Custom Function Default Disabled Selections B9512G Disabled Function 128 to Function 159 B8512G Disabled Function 128 to Function 135 This parameter specifies the custom function that is run when the Auxiliary Function A button is pressed on the RADION keyfob On the RADION four button keyfobs pressing the third button ...

Страница 126: ...toral event is logged Keyfob panic alarm events have a configuration option enabling or disabling their reporting by route group This option is available only from RPS in PANEL WIDE PARAMETERS Report Routing This option controls the reporting of both Keypad Panic Alarms and Keyfob Panic Alarms When a silent panic response is generated the control panel activates the Area Wide Output Duress Output ...

Страница 127: ...ets the menu text displayed at the keypad for the Custom Function item RPS Menu Location Custom Function Custom Function Text 6 2 Custom Function Text Second Language Default Blank Selections Enter up to 32 characters of text numbers and symbols This parameter sets the menu text displayed at the keypad for the Custom Function item when the user keypad or system is configured to use the second lang...

Страница 128: ...ts If the number of faulted points exceeds the Force Arm Bypass Max limit the function fails The control panel does not arm the Area There is no indication at keypads for the failed function The control panel includes the user number in the arming event history log and report If a user activates a Custom Function from a keypad using a shortcut or function key from an RF Keyfob or by presenting the...

Страница 129: ...Level page 221 Access Granted Events page 222 Access Denied Events page 222 Answer RPS page 222 Contact RPS page 222 Contact RPS User Port page 222 Send Status Report page 222 Send Test Report page 223 Send Test on Off Normal page 224 Go to Area page 224 Watch On page 224 Watch Off page 224 Show Date Time page 224 Sound Watch Tone page 224 Set Keypad Volume page 224 Set Keypad Brightness page 225 ...

Страница 130: ...different keypads so they appear in a different order in some areas than they would in others Function Function Function Disabled Item All On Delay All On Instant All On Select Area Part On Delay Part On Instant Part On Select Area Off Off Select Area Extend Close Bypass a Point Unbypass a Point View Area Status View Point Status Send Status Report Reset Sensors Change Output State Fire Walk Test ...

Страница 131: ...nges appear in the Set Clear All Address window RPS Menu Location Shortcut Menu Set Clear All 7 3 Address Default Yes Shortcut Menu 1 to 8 Selections Yes this menu item appears at this keypad address No this menu item does not appear at this keypad address This parameter determines at which keypad address setting this menu item appears Any changes you make in the Set Clear all page 130 window also...

Страница 132: ...put Modules are installed The B8512G control panel supports up to 72 dry contact form C outputs when 9 optional B308 OctoOutput Modules are installed These outputs are used for Area Output Panel Wide Output and Individual Point Fault Outputs Output Follows Point Outputs can also be used to activate when a point programmed for Output Response Type in the point index section is off normal or in alar...

Страница 133: ...intrusion point assigned to this area goes into alarm It will also activate for non fire keypad and keyfob alarms that are configured to sound the Alarm Bell Notice To comply with SIA CP 01 False Alarm Reduction set this parameter to a value other than 0 for each enabled area Refer to SIA CP 01 Verification for more information Burg Time page 100 and Burg Pattern page 101 must be programmed This o...

Страница 134: ...med as Resettable page 199 Scope page 111 must include all the areas that are sharing the output Reset Sensor s page 167 for the user initiating the sensor reset must be enabled in all the areas that are sharing the output Restart Time page 94 must be the same number of seconds for all the areas that are sharing the output Each area can be assigned a unique output number for each of the events lis...

Страница 135: ...n be assigned a unique output number for each of the events listed in this section RPS Menu Location Output Parameters Area Wide Outputs Watch Mode 8 1 7 Area Armed Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 The output activates when the specified area becomes All On exit delay must expire before the output activates The output remains activated until the area is disarmed it does not deac...

Страница 136: ...s to Part On at the end of exit delay the Area Off Output will activate at that time Simply starting entry delay does not affect the state of the output configured in Area Off RPS Menu Location Output Parameters Area Wide Outputs Area Off 8 1 9 Area Fault Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 The output activates whenever a Part On Interior or Interior Follower point is faulted The o...

Страница 137: ...ns RPS Menu Location Output Parameters Area Wide Outputs Silent Alarm 8 1 13 Gas Bell Default 1 Selections B9512G 0 to 599 B8512G 0 to 99 This output activates when a gas point assigned to this area goes into alarm The area wide Gas alarm bell uses the time in Fire Time page 99 and output cadence defined in Gas Pattern page 101 This output activates according to the bell pattern and remains active...

Страница 138: ...line restores A time must be entered in Phone Supervision Time in order for this output to activate RPS Menu Location Output Parameters Panel Wide Outputs Phone Fail 8 2 4 Comm Fail Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 When there is a Comm Fail event for any Route Group the output you enter at this parameter activates The output automatically resets when a report from the Route Grou...

Страница 139: ... Output Parameters Panel Wide Outputs Summary Fire 8 2 7 Summary Alarm Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 This parameter sets the number of the output that activates when a non fire point goes into alarm A steady output is provided until the alarm is silenced and the alarm event is cleared form the keypads display This output does not activate for silent alarms Notice To ensure pr...

Страница 140: ...red to a normal condition and the event message is cleared by the user at the keypad Notice To ensure proper operation do not assign more than one function to the output associated with this summary function Notice Fire gas trouble points must be restored to normal before summary outputs can be cleared RPS Menu Location Output Parameters Panel Wide Outputs Summary Supervisory Fire 8 2 10 Summary T...

Страница 141: ... gas trouble points must be restored to normal before summary outputs can be cleared RPS Menu Location Output Parameters Panel Wide Outputs Summary Supervisory Burg 8 2 12 Summary Gas Output Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 This parameter sets the number of the output that activates when any gas point in the system goes into alarm A steady output is provided until all gas points...

Страница 142: ... Outputs Summary Gas Supervisory Output 8 2 14 Summary Gas Trouble Output Default 0 Selections B9512G 0 to 599 B8512G 0 to 99 This parameter sets the output to activate when any gas point on the control panel is in trouble A steady output is provided until all gas points have restored to a normal condition and the event message is cleared by the user at the keypad Notice To ensure proper operation...

Страница 143: ...e 8 3 2 Output Text Default Output Selections Up to 32 alphanumeric characters This parameter provides a description for the physical location of the point for use by installation and service personnel Enter up to 32 characters of text to describe the output Note To expand or collapse the list of Point numbers use the arrows at the top of the RPS screen RPS Menu Location Output Parameter Output Co...

Страница 144: ...144 en Output Parameters Control Panel 2017 03 09 F 01U 303 998 Program Entry Guide Bosch Security Systems Inc RPS Menu Location Output Parameter Output Configuration Hide from User ...

Страница 145: ...in this group You cannot enter any passcode number that could conflict with a duress passcode Regardless of the Duress Type page 74 setting passcodes within a range of 2 for existing passcodes cannot be entered This rule applies even if duress is disabled For example once a passcode of 654327 is entered 654325 654326 654328 and 654329 cannot be entered A silence bell authority is built into all au...

Страница 146: ...een 8 00 AM and 4 00 PM Between 4 00 PM and 8 00 AM the next day the users cannot use their passcodes To enable this user s passcode at all times leave this item 0 User Group Window times cannot be changed from the keypad Once a window is assigned to a user group the users in that group rely on the window to be active within the start and stop times for their passcodes to function The only way to ...

Страница 147: ... Code to the default 255 for 26 bit card type 65535 for 37 bit with site code card type RPS Menu Location User Configuration User Assignments Site Code 9 1 7 Card Data Default blank Selections 26 bit card type 0 to 65534 blank 37 bit no site code card type 0 to 1099511627774 blank 37 bit with site code card type 0 to 524286 blank Enter the card data printed on the card or token For the 26 bit and ...

Страница 148: ...reless device at the factory It provides a unique way for the wireless receiver and wireless repeaters to identify what device is transmitting Duplicate ID detection is based on the RFID value stored in configuration memory not on the number printed on the device Notice After you Send Updates to Panel the control panel does not download the RFIDs to the receiver until you Disconnect RPS from the C...

Страница 149: ...n panel wide regardless of the user s authority level Enable E Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel wide This function arms all Delay areas that are disarmed When the passcode is entered at the keypad the control panel checks the user s authority level RPS Menu Location User Configuration User Keypad Functions All ...

Страница 150: ... wide This function turns areas part on with entry exit delays in the area where the keypad is assigned Entry and exit delays are provided with this arming function This will not cause a Part On instant point to act as a delay point RPS Menu Location User Configuration User Keypad Functions Part On Delay 9 3 5 Watch Mode Default E Selections E P Disable Disable this function panel wide regardless ...

Страница 151: ...Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel wide This function allows the user to view point status point text and the electrical state normal open short and missing of each point assigned to the area RPS Menu Location User Configuration User Keypad Functions View Point Status 9 3 9 Walk Test all Non Fire Burg Points Defa...

Страница 152: ...ting Reports can also be sent to an IP address if programmed The test report includes additional information if Expand Test Rpt is enabled in the Phone section RPS Menu Location User Configuration User Keypad Functions Send Report Test Status 9 3 12 Door Control Default P Selections E P Disable Disable this function panel wide regardless of the user s authority level Enable E Enable this function ...

Страница 153: ...tion User Configuration User Keypad Functions Change Passcode 9 3 16 Add Edit User Default P Selections E P Disable Disable this function panel wide regardless of the user s authority level Enable E Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel wide This function allows a user with authority to add or change passcodes and a...

Страница 154: ... panel wide This parameter enables or disables the User Command 7 RPS Menu Location User Configuration User Keypad Functions User Command 7 9 3 21 User Command 9 Default P Selections E P Disable Disable this function panel wide regardless of the user s authority level Enable E Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel w...

Страница 155: ...tions Reset Sensors 9 3 25 Change Output Default P Selections E P Disable Disable this function panel wide regardless of the user s authority level Enable E Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel wide This function allows the user to manually set and reset any outputs installed in the system NOTE The Change Outputs p...

Страница 156: ... E Enable this function panel wide without requiring a passcode Passcode P Require a passcode to enable this function panel wide This function displays the control panel s software revision number in the keypad display RPS Menu Location User Configuration User Keypad Functions Display Revision 9 3 29 Service Walk All Points Default P Selections E P Disable Disable this function panel wide regardle...

Страница 157: ...f normal when exiting the Invisible Walk Test are bypassed A trouble tone sounds until it is silenced The keypads will alternate text with the Bypass indications RPS Menu Location User Configuration User Keypad Functions Walk Test All Invisible Burg Points 9 3 32 Silence Function Default E Selections Enable E Enable this function panel wide without requiring a passcode Passcode P Require a passcod...

Страница 158: ...ame 9 4 2 Authority Level Name Second Language Default L1 to L15 Selections Enter up to 32 characters This parameter allows the user to enter a description for an authority level Enter up to 32 characters from the Latin 1 8 bit ISO IEC 8859 1 character set to describe the area Note First and Second languages are programmed during panel account setup in the Panel Data window Supported languages inc...

Страница 159: ...s assigned this authority level This parameter allows users to turn the system All On Delay arm all Part On perimeter and Interior points with exit and entry delay time in areas within the scope of the keypad being used and that correspond to the user s Authority Level If a user uses Command 1 All On Delay only arms the area the keypad is assigned to If a user uses the Remote Security Control app ...

Страница 160: ... for the user who is assigned this authority level Enabled E This function is authorized for the user who is assigned this authority level This parameter allows users to turn the system Part On Delay arm all Part On perimeter points with entry exit and entry delay time in areas within the scope of the keypad being used and that correspond to the user s Authority Level If a user uses Command 3 Part...

Страница 161: ...level This parameter allows the user with this authority level to view all memory events that have occurred since the last time the system was armed for all areas within the scope of the keypad in this area Authority Level 15 is reserved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Authority Levels View Event Memory 9 4 11 View Point Status Default Aut...

Страница 162: ...anel while AC is failed This test includes a two second bell test fire bell output for each fire point that is tested The test ends once all points are tested or until the test times out in 20 minutes of no activity Local alarm annunciation without reporting to the central station receiver Automatic smoke detector reset SENSORS RESETTING for all fire points programmed with Resettable page 199 as Y...

Страница 163: ... an area that is not enabled Area On or points are in an area that is All or Part On When a Service Walk Test is initiated one person can test all the points in the control panel without assistance Points 128 and 248 are not accessible by this function This is normal This function allows viewing of extra points Extra points can occur when Point Source is set to anything other than Unassigned Point...

Страница 164: ...ned this authority level Press the keypad number keys 1 through 8 that correspond to the door number to unlock relock doors For example pressing the 2 and the ENTER keys unlocks door number 2 which is indicated by U in the display Authority Level 15 is reserved for the Service Passcode User 0 You cannot change any settings in the Authority Level 15 column RPS Menu Location User Configuration Autho...

Страница 165: ... this authority level to change and display the date and time for the control panel in this area Authority Level 15 is reserved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Authority Levels Change Date and Time 9 4 22 Change Passcodes Default Authority Levels 1 15 Enabled E Authority Levels 2 14 Blank Selections Blank This function is not authorized fo...

Страница 166: ...the user who is assigned this authority level This parameter allows the user with this authority level to change the closing time in the area where the function is entered Authority Level 15 is reserved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Authority Levels Extend Close 9 4 26 View Event Log Default Authority Levels 1 15 Enabled E Authority Leve...

Страница 167: ...ser Configuration Authority Levels User Command 9 9 4 29 Bypass a Point Default Authority Levels 1 4 15 Enabled E Authority Levels 5 14 Blank Selections Blank This function is not authorized for the user who is assigned this authority level Enabled E This function is authorized for the user who is assigned this authority level This parameter allows the user with this authority level to bypass poin...

Страница 168: ...t OUTPUT ON and reset OUTPUT OFF outputs in the control panel Do not use the CHANGE OUTPUTS function to toggle outputs reserved for special functions Special function outputs are Area and Panel Wide output functions as well as outputs assigned to Enter Key Output page 113 Authority Level 15 is reserved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Autho...

Страница 169: ...erved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Authority Levels Display Panel Type and Revision 9 4 36 Change Skeds Default Authority Levels 1 15 Enabled E Authority Levels 2 14 Blank Selections Blank This function is not authorized for the user who is assigned this authority level Enabled E This function is authorized for the user who is assigned ...

Страница 170: ...e control panel Authority Level 15 is reserved for the Service Passcode User 0 and cannot be changed RPS Menu Location User Configuration Authority Levels Force Arm 9 4 39 Send Area Open Close Default Authority Level 1 14 Enabled E Authority Level 15 Blank Selections Blank This function is not authorized for the user who is assigned this authority level Enabled E This function is authorized for th...

Страница 171: ...ith this authority level to send duress report if the area to which this authority level is assigned sends duress Refer to Duress Enable for more information Configure the Duress Enable parameter to Yes in applicable areas or the keypad will respond with No Authority Duress Disarm Profile User Authority Level 14 is programmed by default as a Duress disarm profile When Duress Type is set to 3 the S...

Страница 172: ...et to 3 the SIA CP 01 compliant Duress Passcode feature is enabled Duress Types 1 and 2 are not allowed in SIA CP 01 compliant installations With Authority Level 14 assigned to a user passcode in an area that user has the authority to disarm and send a Duress event from that area All Duress capable passcodes must be unique and cannot be derived from other passcodes To facilitate this uniqueness Us...

Страница 173: ...d No Disarm Rights Users do not have disarm rights in this area When the user presents a card door reader the panel checks the Access Level and enables area disarm functions as programmed Opening and Closing reports are sent to the central station receiver if programmed For more information on programming this prompt for a Shared area see the Access Control Readers Assigned to the Shared Area para...

Страница 174: ...ce Authority Level 15 is reserved for the Service Passcode User 0 You cannot change any settings in the Authority Level 15 column RPS Menu Location User Configuration Authority Levels Function Level 9 4 48 Keyfob Arm Default Authority Levels 1 6 Enabled E Authority Levels 7 15 Blank Selections Blank This function is not authorized for the user who is assigned this authority level Enabled E This fu...

Страница 175: ...uthority Levels 7 15 Blank Selections Blank This function is not authorized for the user who is assigned this authority level Enabled E This function is authorized for the user who is assigned this authority level When local authorization is required only a security user with the Firmware Update authority enabled can authorize the update Authority Level 15 is reserved for the Service Passcode User...

Страница 176: ...es are allowed When a selection is grayed out you cannot use that option to configure the point For the B9512G control panel the Wireless selection is only available for points 9 to 512 When the Point Source is set to Wireless Output or IP Camera Debounce does not apply RPS automatically selects a dash for Debounce which indicates that Debounce is not applicable Notice Point Source for points 1 8 ...

Страница 177: ...hin a string of text are treated as text and are included in the 32 character limit Notice Include the point number in custom point text This helps the user when viewing events initiating bypasses etc and can simplify troubleshooting To expand or collapse the list of Point numbers use the arrows at the top of the RPS screen RPS Menu Location Points Point Assignments 2nd Language Text 10 1 4 Profil...

Страница 178: ...he point index that is entered in the Index field It is a reference field only and the information displayed in it is not sent to the control panel NOTE To expand or collapse the list of Point numbers use the arrows at the top of the RPS screen RPS Menu Location Points Point Assignments Description 10 1 6 Area Default 1 Selections B9512G 1 to 32 B8512G 1 to 8 Enter the area number you want to assi...

Страница 179: ...d Notice Legacy BFSK Relay or Relay functionality The point assignment parameters for many legacy Bosch control panels include a BFSK Relay or Relay parameter for each point You can easily emulate BFSK Relay functionality by setting this new Output parameter to the same output number for multiple points You can use any output number for any number of points NOTE To expand or collapse the list of P...

Страница 180: ...B810 10 1 10 RADION Device Type Default Blank Selections Glass Break Smoke Inertia Door Window Contact Recessed Door Window Motion Dual Motion PIR Ceiling Mt Motion Universal TX Bill Trap Curtain Motion CO Detector Panic One Button Panic Two Button This parameter allows point source options to be set to wireless If the wireless module type is set to B810 Wireless Device there is no limit on how ma...

Страница 181: ...ned RFIDs can be edited for point replacement or can be set to 0 to disable a RF point An RFID Radio Frequency device Identification number is a unique number assigned to a wireless device at the factory It provides a unique way for the Wireless Receiver and Wireless Repeaters to identify what device is transmitting If the configuration option Wireless Module Type page 252 is set to B820 Inovonics...

Страница 182: ...ints To build point profiles use the parameters in this section Assign Point Profiles to points in Point Assignments 10 3 1 Point Profile Text First Language Default Refer to table below Selections Up to 24 alphanumeric characters Enter up to 24 characters of text to describe the point profile point index Point Profile Point Profile text Point Profile Point Profile text 1 24 Hour Instant Open Shor...

Страница 183: ...ea is disarmed Combining Point Response 9 with the Local While Armed feature provides off site reporting when the area is disarmed but only local alarm annunciation when the area is armed Point Response E Use this for Asic motion detectors This allows troubles to report while the control panel is all on Point Response F will not sound local keypads but will activate Output Response Type and keypad...

Страница 184: ...system 10 3 4 Point Type Point Response page 184 Circuit Style page 202 Default Point Indexes 1 to 2 6 23 31 24 Hour Point Indexes 3 to 5 22 Fire Point Point Indexes 7 9 20 21 24 27 Part On Point Index 10 12 29 30 Interior Point Index 13 28 Interior Follower Point Index 14 Keyswitch Maintained Point Index 15 Keyswitch Momentary Point Index 16 Open Close Point Point Index 17 18 Gas Point Point Inde...

Страница 185: ...hree parameters in a single window Figure 10 1 Point type response circuit style window The Point Response parameter in combination with the Point Type parameter determines how the control panel responds to changes on point sensor loops open short normal for wired points or changes in point states for wireless point devices fault normal trouble The tables below show the Point Response selections f...

Страница 186: ...T I T I Disarmed Fault I I S S Key I instant alarm S supervisory alarm T trouble blank no response Example Point Type 24 hour and Point Response 2 24 hour point with supervisory response for fault and a trouble response for open or short Notice For Dual EOL Circuit Style purchase second 1kΩ EOL separately Order ICP 1K22AWG 10 package of 10 resistors Notice Control panel and B208 Octo input firmwar...

Страница 187: ... Fault T T T T Key I instant alarm D delayed alarm T trouble blank no response Example Point Type Part On and Point Response 1 When the area is on armed a fault on the point circuit creates a delayed alarm response An open or short on the point circuit creates an instant alarm When the area is off disarmed an open or short on the point circuit creates a point trouble There is no response for a fau...

Страница 188: ...med state is disarmarmed Changing the point circuit state from open to normal turns the area on armed state is armed A short on the point circuit creates a point trouble while the area is off disarmed A short on the point circuit while the area is on armed creates an instant alarm When the point circuit returns to normal or open the trouble restores Keyswitch Momentary Point Type Point Response Se...

Страница 189: ...t Type Single EOL Circuit Style Point Response Selections Armed State Circuit State 0 1 2 3 4 5 6 7 8 9 A B C D E F Armed Open CF CF T CF CF CF T CF Armed Short CF CF CF T CF CF CF T Disarmed Open CF CF T CF CF CF T CF Disarmed Short CF CF CF T CF CF CF T Key CF control panel executes custom function on transition to circuit state T trouble blank no response When the point circuit state changes th...

Страница 190: ...for point fault regardless of sensor loop open short state send Open for a tamper event enclosure cover removed Point Response for B810 RADION receiver SD When point Source is set to wireless and a B810 RADION receiver SD module is used wireless points send Open or Short for point fault the electrical state of the sensor loop send Short for the reed switch magnet not present send Tamper for a tamp...

Страница 191: ...ay This parameter enables disables the entry delay warning tone for this point Do not set this parameter to No on points used to notify the user to disarm the system The possibility of false alarms increases if the entry delay warning is not used Entry Tone can also be turned off when programming your Entry Tone page 116 in the keypad section which allows you to manage the tone by keypad You might...

Страница 192: ...al station No Silent Bell page 191 points do not cause the Alarm Bell output to activate even if the report does not get to the central station receiver When set to Yes if the report fails to reach the central station after two attempts a silent alarm rings the alarm bell A silent alarm is generated when a point with Silent Bell set to Yes is alarmed When a point programmed for Silent Bell page 19...

Страница 193: ...and how they are affected by arm state If an alarm trouble or supervisory event occurs and is silenced then Buzz on Fault selections 1 and 3 will persist until the point returns to normal Refer to the following table for Buzz on Fault controlled point operation and 24 hour point operation Selection Buzz on fault Silence while faulted Silence after restore Description 0 Disabled Does not apply Does...

Страница 194: ...tomatically resets when the point is returned to normal 2 The output corresponding with this point latches when the point goes into an alarm condition This output remains on steady output until the alarm is cleared from the keypad display This parameter causes an output to respond when a corresponding point with the same number is faulted Outputs used for this function must not be shared with any ...

Страница 195: ...oints Point Indexes Local While Disarmed 10 3 17 Local While Armed Default No Selections Yes No Yes Suppress alarm trouble and restoral reports from this point while the area it is assigned to is armed No Report events occurring from this point while the area is armed Use this parameter to allow a controlled point Part On Interior and Interior Follower to report alarms troubles and restoral report...

Страница 196: ... point is assigned to is disarmed Set this parameter to No for interlock points When not allowed to return to the system through disarming the point must be manually unbypassed using the UNBYPASS keypad function Sked functions Unbypass a Point or Unbypass All Points or remotely using RPS For force armed points to remain bypassed ensure Force Arm Returnable page 196 is set to No RPS Menu Location P...

Страница 197: ...r of events an hour the count is reset to zero Bypassable page 196 does not need to be set to Yes for swinger bypass to work A swinger shunted point returns to the system if Bypass Returnable page 196 is set to Yes If not return the point to the system as described in Bypass Returnable RPS Menu Location Points Point Indexes Swinger Bypass 10 3 23 Report Bypass at Occurrence Default No Selections Y...

Страница 198: ...Points 1 8 Cross Points 9 16 and so on A minimum of two points must be programmed to meet the cross point criteria Point numbers from different cross point groups do not affect each other When a point with this parameter set to Yes detects an alarm the control panel starts the cross point timer If a second cross point in the same cross point group detects an alarm while the cross point timer is ac...

Страница 199: ...3 No Point Profiles 4 5 Yes Selections Yes This point is reset by the RESET SENSORS function and during the alarm verification sequence No This point is not resettable Use this parameter if this is a powered point that requires interruption of power to reset a latched alarm event The resettable point function is typically used with smoke detectors and glass break detectors When a sensor reset is i...

Страница 200: ...rs Selections None Disable wireless point supervision 4 12 24 48 72 Set the length of time in hours for wireless point supervision This parameter sets the length of time in hours between failure events to hear from the wireless transmitter before sending a missing event for devices configured to report to the Wireless Receiver RADION keyfobs will follow the supervision rules if configured as a poi...

Страница 201: ...Response Disarmed Default 00 00 Selections 00 05 thru 60 00 00 00 disabled This parameter sets the length of time MM SS the control panel waits after a disarmed point faults before annunciating or reporting the fault This parameter only applies to the following point types when armed Part On page 203 Interior page 204 Interior Follower page 204 Use this feature to delay the effect of the following...

Страница 202: ...L No EOL This parameter sets the circuit style for a point index Notice Circuit Style control panel firmware requirements The Circuit Style Parameter is not available for control panel firmware v2 xx The Dual EOL resistor configuration is available only for control panel firmwarev3 01 and higher The Single EOK 2KΩ selection is only for control panel firmware v3 03 and higher The No EOL selection i...

Страница 203: ...otection you should consider using the Buzz On Fault and Local While Disarmed page 194 options Hold up devices in UL installations the 24 Hour point type must be used for points connected to hold up devices The point text must include hold up 10 4 2 Part On Configuring a point profile with the Part On point type makes it a Part On point profile Points assigned to a Part On point profile are Point ...

Страница 204: ...is less than the remaining time it shortens the entry delay time Delayed points can also initiate an entry tone at the keypad Refer to Entry Tone Off page 191 Notice Use the Interior Follower page 204 profile for instant alarm if the area is not in entry delay For some installations you may want an interior point that follows but can not initiate entry day Tripping an Interior Follower point while...

Страница 205: ...d Short A short is a trouble while the area is disarmed A short is an alarm while the area is armed When this point changes from shorted to normal or open it restores Trouble and restoral reports are not sent if Local While Disarmed page 194 is set to Yes Alarm and restoral reports are not sent if Local While Armed page 195 is set to Yes Notice Point Response 2 is required for Inovonics FA113 Wire...

Страница 206: ...ly When the point is in an off normal state the control panel waits for the time programmed in AC Fail Time before generating a Point Trouble This point type does not use Point Response page 184 therefore no alarm event occurs If this point type is bypassed 24 HOUR PT BYPASSED is shown on the keypads 10 4 10 Gas Point This point type monitors gas detection sensors and generates a Gas Alarm when an...

Страница 207: ...g window times 11 1 1 Opening window timeline Example using two opening windows on the same day Areas that are disarmed between midnight and 6 AM generate Opening reports Areas that are disarmed between 6 AM and 7 AM generate Early to Open reports If the area is disarmed between 7 AM and 8 AM regular Opening Reports are generated If Disable O C in Window is programmed as yes the Opening Report is ...

Страница 208: ...area that opens between 11 30 PM and 12 30 AM five days a week use two windows as shown in the example below Programming to Link Two Days Over Midnight Open Close W Early begin Start Stop Early begin Start Stop Except on Holiday Holiday index Area s 1 Monday 22 00 23 30 23 59 Yes No 1234 123456 78 2 Monday 00 00 00 00 00 30 Yes No 1234 123456 78 11 1 2 Opening_Closing windows table Monday to Frida...

Страница 209: ...lidays NO Select at least one Index Program at least on area as YES 11 1 3 Sunday through Saturday Default Sunday through Saturday No Selections Yes No In the seven weekday parameters select the days of the week that the opening and or closing windows are active To prevent the windows from activating on certain days of the year set Xept Holiday page 215 to Yes and enable at least one holiday index...

Страница 210: ...to Open modifier When configuring multiple windows to operate on the same day ensure that they are added to the system in chronological order For example if three windows are programmed to execute on Tuesday Window 1 W1 must occur before Window 2 W2 and Window 2 must occur before Window 3 W3 Avoid programming the Open Early Begin time before a time that is between another window s Open Window Star...

Страница 211: ...isable HH MM hours and minutes 00 00 to 23 59 This parameter is one of three required to create a closing window To finish programming a closing window Close Window Start page 212 and Close Window Stop page 212 must be programmed The time entered in this parameter is the earliest time the user can close an area before the Close Window Start time If opening and closing reports are enabled arming th...

Страница 212: ...f the area is not armed when the Close Window Start time comes To temporarily silence the tone press the ESC key on the keypad The warning tone restarts in 10 minutes if the area is not armed Refer to Close Early Begin page 211 for report feature explanations RPS Menu Location Schedules Open Close Windows Close Window Start 11 1 9 Close Window Stop Default Disable Selections Disable HH MM hours an...

Страница 213: ...n the days of the week programmed unless the date is designated as a holiday by the selected holiday index es To use this parameter the window must be programmed to activate on at least one day of the week and a holiday index must be enabled You also use this selection if opening and or closing windows are only needed on certain days of the year Do not program the windows to execute on any days of...

Страница 214: ...ed to a User Window the passcode for that user is enabled all the time 11 2 1 User Group Default window Selections B9512G 0 to 32 B8512G 0 to 8 0 disabled Enter a number to identify the group of users in this parameter When this window runs the user passcodes for this group are enabled disabled You can assign a user group to more than one window in a 24 hour period but the windows must not overlap...

Страница 215: ... same day that you are programming it do a Reset Panel command after programming RPS Menu Location Schedules User Group Windows Group Enable Time 11 2 4 Group Disable Time Default Disable Selections Disable HH MM hours and minutes Enter the time of day when the window ends This time marks the end of the period in which users assigned to this window s group can use their passcodes The window stops ...

Страница 216: ...e must be made to what is affected by the function e g When choosing a Disarm Sked the disarming is the function while the areas that are being chosen to become disarmed are what is affected The functions and their associated parameters are explained in detail following the Function parameter Each Sked can be programmed with up to four Holiday Indexes The Holiday Indexes can be used to execute the...

Страница 217: ...e All On No Exit feature is ignored when arming from a SKED Click on a function name for information about that function Not In Use This function is disabled and no functions after this will be performed All On Delay page 219 All On Instant page 220 Part On Delay page 220 Part On Instant page 220 Disarm page 220 Extend Close page 220 Bypass a Point page 220 Unbypass a Point page 220 Unbypass All P...

Страница 218: ...ed time 4 Click on OK Follow these steps to Disable a Sked 1 Double click on the field corresponding to the Sked you wish to disable 2 Select Disable 3 Click OK RPS Menu Location Schedules Skeds Time 11 3 6 Date Default Disable Selections Disable Day Month ex 12 June Enter the date that the Sked executes Disabled Skeds display Disabled in the Date cell RPS Menu Location Schedules Skeds Date 11 3 7...

Страница 219: ...u want this window to activate only on specific dates RPS Menu Location Schedules Skeds Holiday 11 4 Holiday indexes 11 4 1 Schedule Holiday Indexes Schedule This parameter sets holidays Within each index you can select up to 365 dates or 366 dates for a Leap Year to be designated as Holidays Double click in a cell corresponding to the Holiday Index you wish to program The Holiday Schedule dialog ...

Страница 220: ...ber of minutes configured in Parameter 2 This function can only take effect after the Close Early Begin time has passed Notice Extend Close time cannot extend past midnight Furthermore if enabled it cannot extend past an area s configured Latest Close Time 11 5 7 Bypass a Point This function emulates the Bypass Point keypad function The entry in the Parameter 1 Point prompt defines the point this ...

Страница 221: ...ked or custom function This is a panel wide function No other parameters require input for this option 11 5 16 Delay Use this function to create a configurable delay 0 to 90 seconds between or before functions Parameter 1 configures the delay 11 5 17 Cycle Door This function emulates the Cycle Door keypad shortcut function and is only available in a Custom Function This function momentarily unlock...

Страница 222: ...he keypad short cut Answer RPS which causes the control panel to answer the next request from RPS to establish a session via phone or network This function is only available in a custom function This auto answer period will last for 2 minutes and overrides the Answer RPS Over Network and RPS Address Verification prompt settings 11 5 25 Contact RPS This function attempts to contact an Unattended RP...

Страница 223: ... for the sked on the date entered in the Date parameter The Send Test Report sked runs every month after that Scheduled The Send Test Report sked runs annually on the date entered in Date parameter at the time entered in the Time parameter Deferring test reports When Parameter 1 Deferred is set to Yes the control panel starts or restarts a 24 hour countdown timer each time it receives an Ack ackno...

Страница 224: ...ea 11 5 31 Watch On This function emulates the operation of the keypad shortcut Change Watch Mode by activating Match mode for the areas programmed in Parameter 1 Area Watch mode causes a chime at any keypad within scope when a watch point is faulted while disarmed 11 5 32 Watch Off This function emulates the operation of the keypad shortcut Change Watch Mode by deactivating Match mode for the are...

Страница 225: ...37 Trouble Silence This function is not available as a Keypad Shortcut but can be performed at any keypad through other means When activated this function silences all trouble tones and system buzzes in the areas programmed in Parameter 1 Area 11 5 38 Alarm Silence This function is not available as a Keypad Shortcut but can be performed at any keypad through other means When activated this functio...

Страница 226: ...e Text 12 1 2 Door Name Text second language Default blank Selections Up to 32 alphanumeric characters Notice The B9512G supports Doors 1 to 32 on an SDI2 bus or Doors 1 to 8 on an SDI bus The B8512G supports Doors 1 to 8 Enter up to 24 characters of text to describe the door This is for informational purposes only and is not programmed in the control panel RPS Menu Location Access Doors Door Name...

Страница 227: ...cess Doors Associated Keypad 12 1 6 Custom Function Default Disabled Selections B9512G Disabled CF128 to CF159 B8512G Disabled CF128 to CF135 Disabled Custom function is disabled CF The custom function number that activates when a valid ID is entered given the appropriate user access level and area arm state Use this parameter to program a custom function that activates at the keypad programmed fo...

Страница 228: ... Response of 9 to C for instant alarm response when the area is on armed or off disarmed If you select an on board point points 1 8 as a Door Point be sure there is no EOL resistor connected to the sensor loop on the control panel RPS Menu Location Access Doors Door Point See also Debounce page 178 12 1 8 Door Point Debounce Default 600 ms Selections Debounce 300 ms 1800 ms 3300 ms 600 ms 2100 ms ...

Страница 229: ...door request You may use the same point as the Interlock Point for multiple access control modules Sharing a point as the Interlock point for multiple modules allows one faulted point to prevent multiple modules from granting access The interlock point will be considered in a normal state if it is bypassed swinger bypassed or forced armed This results in normal operation of access even if the door...

Страница 230: ... Enter functions use the token reader for authentication and prevent all door functions including Fire Unlock RPS Menu Location Access Doors Fire Unlock 12 1 12 Disarm on Open Default No Selections Yes the area only disarms after access has been granted to a user with disarm authority and the door point has been faulted door was opened No the area disarms when a user with a valid disarm level pres...

Страница 231: ...remains open At the end of the programmed Extend Time the buzzer continues to buzz until the door closes In addition if programmed the point assigned to the door indicates a Trouble Alarm or Fault at the keypad Regardless of the door point programming the system generates a Trouble Door Left Open event while the system is disarmed and an Alarm Door Left Open event when the system is armed and the ...

Страница 232: ...y without relying on a token card to activate the strike such as with a push bar Notice No RTE Events when RTE Shunt Only is set to Yes When RTE Shunt Only is set to Yes the control panel does not log or report Request To Enter events when the RTE Input is shorted RPS Menu Location Access Doors RTE Shunt Only 12 1 19 RTE Input Debounce Default 600 ms Selections Debounce 300 ms 1800 ms 3300 ms 600 ...

Страница 233: ...scans the REX input before initiating a request to exit REX event For appropriate settings consult the manufacturer s instructions for the device connected to the REX input RPS Menu Location Access Doors REX Input Debounce 12 1 22 Access Granted Default Yes Selections Yes ACCESS GRANTED and DOOR REQUEST events logged and reported No ACCESS GRANTED and DOOR REQUEST events are not logged or reported...

Страница 234: ... REQUEST TO EXIT REX events logged and reported No REQUEST TO EXIT REX events are not logged and reported This parameter determines if REQUEST TO EXIT REX events from this access control module are logged and reported by the control panel RPS Menu Location Access Doors Enter Request 12 1 26 Failure Mode Default Fail secure Selections Fail Secure Door remains locked to ensure continued security Fai...

Страница 235: ...ion Access Doors Enclosure Tamper See also Door Point page 228 12 2 Global Access settings 12 2 1 Card Type Default 26 bit Selections 26 bit 37 bit no site code 37 bit with site code This parameter specifies the card or token format used for all of the door controllers and keypads Notice Set to 26 bit when credentials card or token are used with a B942 Default Site Code page 147 for card types 26 ...

Страница 236: ...nt Disarmed Area Entry Delay Part On Entry Delay Area Exit Delay Part On Exit Delay the control panel status AC fail battery missing AC restore battery low and so on and output status output on or output off Entries are in 500 millisecond increments Therefore if a 5 is entered the Status information is sent every 500 milliseconds or second An entry of 10 would equal 1 second If the Status Rate is ...

Страница 237: ...with Bosch RSC is an application example RPS Menu Location Automation Remote App Remote App 13 6 Remote App Passcode Default RPS generated random 24 character passcode Selections Up to 24 characters Use this parameter to set the passcode the panel receives from a remote application to establish a secure connection smart phone with Bosch RSC is an application example The passcode length is 6 to 24 ...

Страница 238: ...able Selections Yes Enable enclosure tamper input No Disable enclosure tamper input This parameter enables the enclosure tamper switch input on the SDI2 module When the input is enabled and connected to a Bosch ICP EZTS tamper switch installed in the module enclosure the control panel can create a tamper event when the enclosure door is opened or when the enclosure is removed from the wall RPS Men...

Страница 239: ...ules Panel type Modules supported B9512G 59 B8512G 9 Tab 14 3 Capacity Settings RPS supports the configuration of the Enclosure Tamper page 238 on each of the Octo output modules Yes Enable enclosure tamper No Disable enclosure tamper The default setting is No Switch Settings Refer to Hardware Switch Settings B308 Octo output Module switch settings page 260 14 3 1 Module Enclosure Tamper Default N...

Страница 240: ...If the module is configured through the B42x configuration web interface to disable control panel programming that is Panel Programming Enable is set to No then RPS programming of the B42x is accepted by the control panel but not applied to the B42x The Panel Programming Enable parameter is not available in RPS 14 4 1 Module Enclosure Tamper Default No Disable Selections Yes Enable enclosure tampe...

Страница 241: ...P AutoIP Enable 14 4 4 IPv4 Address Default 0 0 0 0 Selections 0 0 0 0 to 255 255 255 255 This parameter sets the IPv4 address If the IPv4 DHCP Auto IP Enable parameter is set to Yes this parameter is grayed out you do not have access to it If the IPv4 DHCP Auto IP Enable parameter is set to No enter the IPv4 address here Further Information IP Address and Domain Name formats page 282 This paramet...

Страница 242: ...s parameter sets the IPv4 DNS server address in Static IP mode A Domain Name Server DNS converts internet domain names or hostnames to their corresponding IP addresses In DHCP mode the DHCP server s default DNS is used To use a custom DNS server in DHCP mode change this parameter to the custom DNS server s IP address Further information IP Address and Domain Name formats page 282 RPS Menu Location...

Страница 243: ...er When TLS Enhanced Security is enabled HTTPS is applied The default value for HTTPS is 443 If enhanced security is not enabled the HTTP value is applied RPS Menu Location SDI2 Modules IP Communicator HTTP Port Number 14 4 11 ARP Cache Timeout sec Default 600 Selections 1 to 600 seconds This parameter specifies the time out for ARP cache entries time out value in seconds The parameter has no effe...

Страница 244: ...hostname externally you must enter the hostname in the DNS server You can use the hostname to connect to the control panel with RPS or RSC Remote Security Control or for module web configuration and diagnostics The parameter has no effect on B450 Plug in Communicator Interface operation RPS Menu Location SDI2 B42x IP Communicator Module Hostname 14 4 16 Unit Description Default Blank Selections Up...

Страница 245: ...ks The control panel uses the IP communicator to ping the IPv4 Test Address to verify the integrity of the network and the network configuration settings RPS Menu Location SDI2 B42x IP Communicator IPv4 Test Address 14 4 20 IPv6 Test Address Default 2001 4860 4860 8888 Selections IPv6 address or Domain Name The default test address works for most networks This parameter is only available when IPv6...

Страница 246: ...ddress has a hexadecimal notation which consists of the eight groups of the address expressed separately in hexadecimal and separated by colons Each group has a value between 0000 FFFF When this is defined through the DHCP service leave the default value If the module fails to obtain an address from the primary server the Alternate IPV6 DNS server is used if specified The module can use the Altern...

Страница 247: ...ep alive period 14 5 3 Inactivity Time Out min Notice Important configuration information for cellular communication Refer to Configuring for Cellular Service page 280 for an overview and configuration information Default 0 Selections 0 to 1000 minutes 0 Disabled Panel does not verify the connection is active 1 to 1000 Enabled Panel verifies an active connection exists This parameter specifies the...

Страница 248: ...ew and configuration information Default 0 Selections 0 3600 seconds 0 Disabled 1 to 3600 Enabled When there are no towers present the control panel starts two timers one for a No Towers event one for a No IP Address event The control panel uses the duration set by this Reporting Delay for No Tower parameter for both timers If the cellular plug in module does not find a tower before the end of the...

Страница 249: ...ent If the cellular plug in module successfully registers with one or more towers but does not receive an IP address within 60 seconds the control panel creates a No IP Address event RPS menu location SDI2 modules IP Communicator B450 Cellular Reporting delay for no towers 14 5 7 SIM PIN Notice Important configuration information for cellular communication Refer to Configuring for Cellular Service...

Страница 250: ...cation SDI2 modules IP Communicator B450 Cellular Network access point user name 14 5 10 Network Access Point Password Notice Important configuration information for cellular communication Refer to Configuring for Cellular Service page 280 for an overview and configuration information Default Blank Selections 0 30 ASCII characters This parameter sets the password required to access the Network Acc...

Страница 251: ...u Location SD12 B520 Power Supply Module Enable 14 6 2 Module Enclosure Tamper Default No Disable Selections Yes Enable enclosure tamper input No Disable enclosure tamper input This parameter enables the enclosure tamper switch input on the SDI2 module When the input is enabled and connected to a Bosch ICP EZTS tamper switch installed in the module enclosure the control panel can create a tamper e...

Страница 252: ...nfigured to report to the Wireless Receiver RPS supports the configuration of the Low Battery Resound page 253 on each of the Wireless Receiver modules Switch Settings Refer to B810 B820 Hardware switch settings page 256 14 7 1 Wireless Module Type Default B810 RADION Wireless Selections Unassigned B810 RADION Wireless B820 Inovonics Wireless This parameter configures the system for either a RADIO...

Страница 253: ... hours set by this parameter the control panel creates a missing repeater event Notice Wireless Point Supervision Time Configure the wireless supervision time for non fire points using the parameter Point Profiles Wireless Point Supervision Time page 200 The wireless point supervision time for fire points is fixed at 4 hours Notice Wireless Keyfob Supervision Time Enable or disable wireless superv...

Страница 254: ...e Settings You can configure the Enclosure Tamper on each of the wireless repeater modules Yes default Enable enclosure tamper No Disable enclosure tamper You can configure the RFID for each of the Wireless Repeater modules There are no hardware switches on a wireless repeater The location of the RFID within the configuration table determines the wireless repeater number Notes Even though RPS list...

Страница 255: ...2000 but cannot exceed more than 1000 devices in total RPS Menu Location SDI2 Modules Wireless Repeater RFID B810 RADION Wireless 14 8 3 Inovonics RFID B820 Default N A Range 0 99999999 This parameter provides a unique way for the Wireless Receiver and Wireless Repeaters to identify what device is transmitting The RFID Radio Frequency device Identification number is a unique number assigned to a w...

Страница 256: ...3 4 5 6 1 ON ON ON ON Encoding Tone ON OFF ON 2 OFF ON ON ON ON 3 ON OFF ON ON ON 4 OFF OFF ON ON ON 5 ON ON OFF ON ON 6 OFF ON OFF ON ON 7 ON OFF OFF ON ON 8 OFF OFF OFF ON ON 9 ON ON ON OFF ON 10 OFF ON ON OFF ON 11 ON OFF ON OFF ON 12 OFF OFF ON OFF ON 13 ON ON OFF OFF ON 14 OFF ON OFF OFF ON 15 ON OFF OFF OFF ON 16 OFF OFF OFF OFF ON B91x Basic Keypad address switch settings Address Switches 1...

Страница 257: ...F ON OFF ON OFF 21 ON OFF ON OFF ON OFF 22 OFF ON ON OFF ON OFF 23 ON ON ON OFF ON OFF 24 OFF OFF OFF ON ON OFF 25 ON OFF OFF ON ON OFF 26 OFF ON OFF ON ON OFF 27 ON ON OFF ON ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF 32 OFF OFF OFF OFF OFF ON B92x Two line Keypad B93x ATM Style Keypad address switch settings Set the address switches per the...

Страница 258: ...escribes the relationship between the module switch settings and the point address range that corresponds to the setting The values of point range listed in this table references back to POINTS Point Assignments The B9512G supports up to 59 B208 Octo input modules The B8512G supports up to 9 modules Terminate unused B208 inputs with an EOL resistor B208 address number B9512G point numbers B8512G p...

Страница 259: ...t numbers 23 231 238 24 241 248 25 251 258 26 261 268 27 271 278 28 281 288 29 291 298 30 301 308 31 211 208 32 321 328 33 331 338 34 341 348 35 351 358 36 361 368 37 371 378 38 381 388 39 391 398 40 401 408 41 411 408 42 421 428 43 431 438 44 441 448 45 451 458 46 461 468 47 471 478 48 481 488 49 491 498 50 501 508 51 511 508 52 521 528 53 531 538 54 541 548 55 551 558 ...

Страница 260: ...ts The B9512G supports up to 5 modules The B8512G supports 1 module B299 address number B9512G point numbers B8512G point numbers 0 9 99 9 99 1 100 199 2 200 299 3 300 399 4 400 499 5 500 599 15 4 B308 Octo output Module switch settings This table describes the relationship between the module switch settings and the output number range that corresponds to the setting The B9512G supports up to 59 B...

Страница 261: ...ut numbers 13 131 138 14 141 148 15 151 158 16 161 168 17 171 178 18 181 188 19 191 198 20 201 208 21 211 208 22 221 228 23 231 238 24 241 248 25 251 258 26 261 268 27 271 278 28 281 288 29 291 298 30 301 308 31 211 208 32 321 328 33 331 338 34 341 348 35 351 358 36 361 368 37 371 378 38 381 388 39 391 398 40 401 408 41 411 408 42 421 428 43 431 438 44 441 448 45 451 458 ...

Страница 262: ...is table describes the relationship between the module switch settings and type of control panel communication that corresponds to the setting B426 switch setting Address Bus type Function 0 Local configuration setting default setting 1 1 173 SDI2 Automation or RPS reporting 15 6 B450 Cellular Module switch settings This table describes the relationship between the module switch settings and type ...

Страница 263: ...dule s address The module uses address 1 Addresses 0 and 2 through 9 are invalid 15 9 B820 Inovonics wireless receiver switch settings The B820 Inovonics address switches provide a single digit setting for the module s address The module uses addresses 1 through 4 Addresses 0 and 5 through 9 are invalid Only address 1 is valid for these control panels 15 10 B901 Access Module switch settings Two a...

Страница 264: ...7 to 24 ON ON ON OFF 137 to 144 25 to 32 ON ON OFF ON 145 to 152 33 to 40 ON ON OFF OFF 153 to 160 41 to 48 ON OFF ON ON 161 to 168 49 to 56 ON OFF ON OF 169 to 176 57 to 64 ON OFF OFF ON 177 to 184 65 to 72 ON OFF OFF OFF 185 to 192 73 to 80 OFF ON ON ON 193 to 200 81 to 88 OFF ON ON OFF 201 to 208 89 to 96 OFF ON OFF ON 209 to 216 97 to 104 OFF ON OFF OFF 217 to 224 105 to 112 OFF OFF ON ON 225 ...

Страница 265: ... to those terminals to the ON position Point Switches To enable each point sensor loop on an OctoPOPIT set its point switch to the ON position To disable each point sensor loop on an OctoPOPIT set its point switch to the OFF position Notice Point switch 8 must be OFF for a D8128D set to points 121 to 127 or 241 to 247 For D8128D OctoPOPITs set to points 121 to 127 or points 241 to 247 you must set...

Страница 266: ...ON ON ON ON OFF OFF OFF 108 ON ON ON OFF ON ON ON 9 109 ON ON ON OFF ON ON OFF 10 110 ON ON ON OFF ON OFF ON 11 111 ON ON ON OFF ON OFF OFF 12 112 ON ON ON OFF OFF ON ON 13 113 ON ON ON OFF OFF ON OFF 14 114 ON ON ON OFF OFF OFF ON 15 115 ON ON ON OFF OFF OFF OFF 16 116 ON ON OFF ON ON ON ON 17 117 ON ON OFF ON ON ON OFF 18 118 ON ON OFF ON ON OFF ON 19 119 ON ON OFF ON ON OFF OFF 20 120 ON ON OFF...

Страница 267: ... 137 ON OFF ON ON OFF ON OFF 38 138 ON OFF ON ON OFF OFF ON 39 139 ON OFF ON ON OFF OFF OFF 40 140 ON OFF ON OFF ON ON ON 41 141 ON OFF ON OFF ON ON OFF 42 142 ON OFF ON OFF ON OFF ON 43 143 ON OFF ON OFF ON OFF OFF 44 144 ON OFF ON OFF OFF ON ON 45 145 ON OFF ON OFF OFF ON OFF 46 146 ON OFF ON OFF OFF OFF ON 47 147 ON OFF ON OFF OFF OFF OFF 48 148 ON OFF OFF ON ON ON ON 49 149 ON OFF OFF ON ON ON...

Страница 268: ...ON 67 167 OFF ON ON ON ON OFF OFF 68 168 OFF ON ON ON OFF ON ON 69 169 OFF ON ON ON OFF ON OFF 70 170 OFF ON ON ON OFF OFF ON 71 171 OFF ON ON ON OFF OFF OFF 72 172 OFF ON ON OFF ON ON ON 73 173 OFF ON ON OFF ON ON OFF 74 174 OFF ON ON OFF ON OFF ON 75 175 OFF ON ON OFF ON OFF OFF 76 176 OFF ON ON OFF OFF ON ON 77 177 OFF ON ON OFF OFF ON OFF 78 178 OFF ON ON OFF OFF OFF ON 79 179 OFF ON ON OFF OF...

Страница 269: ...FF ON OFF OFF OFF OFF OFF 96 196 OFF OFF ON ON ON ON ON 97 197 OFF OFF ON ON ON ON OFF 98 198 OFF OFF ON ON ON OFF ON 99 199 OFF OFF ON ON ON OFF OFF For use with the B500 retrofit module Points 009 to 048 Address DIP switch 0 1 2 3 4 5 6 009 ON ON ON ON ON ON ON 010 ON ON ON ON ON ON OFF 011 ON ON ON ON ON OFF ON 012 ON ON ON ON ON OFF OFF 013 ON ON ON ON OFF ON ON 014 ON ON ON ON OFF ON OFF 015 ...

Страница 270: ... ON ON OFF ON OFF OFF OFF 033 ON ON OFF OFF ON ON ON 034 ON ON OFF OFF ON ON OFF 035 ON ON OFF OFF ON OFF ON 036 ON ON OFF OFF ON OFF OFF 037 ON ON OFF OFF OFF ON ON 038 ON ON OFF OFF OFF ON OFF 039 ON ON OFF OFF OFF OFF ON 040 ON ON OFF OFF OFF OFF OFF 041 ON OFF ON ON ON ON ON 042 ON OFF ON ON ON ON OFF 043 ON OFF ON ON ON OFF ON 044 ON OFF ON ON ON OFF OFF 045 ON OFF ON ON OFF ON ON 046 ON OFF ...

Страница 271: ...N OFF ON ON 62 ON OFF OFF ON OFF ON OFF 63 ON OFF OFF ON OFF OFF ON 64 ON OFF OFF ON OFF OFF OFF 65 ON OFF OFF OFF ON ON ON 66 ON OFF OFF OFF ON ON OFF 67 ON OFF OFF OFF ON OFF ON 68 ON OFF OFF OFF ON OFF OFF 69 ON OFF OFF OFF OFF ON ON 70 ON OFF OFF OFF OFF ON OFF 71 ON OFF OFF OFF OFF OFF ON 72 ON OFF OFF OFF OFF OFF OFF 73 OFF ON ON ON ON ON ON 74 OFF ON ON ON ON ON OFF 75 OFF ON ON ON ON OFF O...

Страница 272: ...N OFF ON 092 OFF ON OFF ON ON OFF OFF 093 OFF ON OFF ON OFF ON ON 094 OFF ON OFF ON OFF ON OFF 095 OFF ON OFF ON OFF OFF ON 096 OFF ON OFF ON OFF OFF OFF 097 OFF ON OFF OFF ON ON ON 098 OFF ON OFF OFF ON ON OFF 099 OFF ON OFF OFF ON OFF ON 100 OFF ON OFF OFF ON OFF OFF 101 OFF ON OFF OFF OFF ON ON 102 OFF ON OFF OFF OFF ON OFF 103 OFF ON OFF OFF OFF OFF ON 104 OFF ON OFF OFF OFF OFF OFF 105 OFF OF...

Страница 273: ...N ON 122 OFF OFF OFF ON ON ON OFF 123 OFF OFF OFF ON ON OFF ON 124 OFF OFF OFF ON ON OFF OFF 125 OFF OFF OFF ON OFF ON ON 126 OFF OFF OFF ON OFF ON OFF 127 OFF OFF OFF ON OFF OFF ON 128 OFF OFF OFF OFF OFF OFF OFF Points 129 to 168 Address DIP switch 0 1 2 3 4 5 6 129 ON ON ON ON ON ON ON 130 ON ON ON ON ON ON OFF 131 ON ON ON ON ON OFF ON 132 ON ON ON ON ON OFF OFF 133 ON ON ON ON OFF ON ON 134 O...

Страница 274: ...F ON OFF 151 ON ON OFF ON OFF OFF ON 152 ON ON OFF ON OFF OFF OFF 153 ON ON OFF OFF ON ON ON 154 ON ON OFF OFF ON ON OFF 155 ON ON OFF OFF ON OFF ON 156 ON ON OFF OFF ON OFF OFF 157 ON ON OFF OFF OFF ON ON 158 ON ON OFF OFF OFF ON OFF 159 ON ON OFF OFF OFF OFF ON 160 ON ON OFF OFF OFF OFF OFF 161 ON OFF ON ON ON ON ON 162 ON OFF ON ON ON ON OFF 163 ON OFF ON ON ON OFF ON 164 ON OFF ON ON ON OFF OF...

Страница 275: ...F ON 180 ON OFF OFF ON ON OFF OFF 181 ON OFF OFF ON OFF ON ON 182 ON OFF OFF ON OFF ON OFF 183 ON OFF OFF ON OFF OFF ON 184 ON OFF OFF ON OFF OFF OFF 185 ON OFF OFF OFF ON ON ON 186 ON OFF OFF OFF ON ON OFF 187 ON OFF OFF OFF ON OFF ON 188 ON OFF OFF OFF ON OFF OFF 189 ON OFF OFF OFF OFF ON ON 190 ON OFF OFF OFF OFF ON OFF 191 ON OFF OFF OFF OFF OFF ON 192 ON OFF OFF OFF OFF OFF OFF 193 OFF ON ON ...

Страница 276: ... 209 OFF ON OFF ON ON ON ON 210 OFF ON OFF ON ON ON OFF 211 OFF ON OFF ON ON OFF ON 212 OFF ON OFF ON ON OFF OFF 213 OFF ON OFF ON OFF ON ON 214 OFF ON OFF ON OFF ON OFF 215 OFF ON OFF ON OFF OFF ON 216 OFF ON OFF ON OFF OFF OFF 217 OFF ON OFF OFF ON ON ON 218 OFF ON OFF OFF ON ON OFF 219 OFF ON OFF OFF ON OFF ON 220 OFF ON OFF OFF ON OFF OFF 221 OFF ON OFF OFF OFF ON ON 222 OFF ON OFF OFF OFF ON ...

Страница 277: ...OFF ON OFF OFF OFF ON 240 OFF OFF ON OFF OFF OFF OFF 241 OFF OFF OFF ON ON ON ON 242 OFF OFF OFF ON ON ON OFF 243 OFF OFF OFF ON ON OFF ON 244 OFF OFF OFF ON ON OFF OFF 245 OFF OFF OFF ON OFF ON ON 246 OFF OFF OFF ON OFF ON OFF 247 OFF OFF OFF ON OFF OFF ON 248 OFF OFF OFF OFF OFF OFF OFF RPS Menu Location Hardware Switch Settings D9127 POPITs switch settings 15 14 D9210 Access Interface Module sw...

Страница 278: ...ches 5 and 6 must stay in the ON position To enable SDI Fail Mode set DIP switch 4 to ON To disable SDI Fail Mode set DIP switch 4 to OFF D9210C Fail mode Central station Modem4 SDI address setting Keypad display UNLOCKED SDI 33 81 Door 1 UNLOCKED SDI 34 82 Door 2 UNLOCKED SDI 35 83 Door 3 UNLOCKED SDI 36 84 Door 4 UNLOCKED SDI 37 85 Door 5 UNLOCKED SDI 38 86 Door 6 UNLOCKED SDI 39 87 Door 7 UNLOC...

Страница 279: ... Bosch Security Systems Inc Program Entry Guide 2017 03 09 F 01U 303 998 Fail mode Central station Modem4 SDI address setting Keypad display LOCKED SDI 40 98 Door 8 RPS Menu Location Hardware Switch Settings D9210 Access Interface switch settings ...

Страница 280: ...re RPS for cellular service 1 Click Config to open the Configuration menu Click System 2 Click the Connectivity tab 3 Click Cellular 4 If you will connect from the internet to the panel using cellular IP over a PPTP VPN a login is provided with Bosch Cellular click the VPN tab This one time setup automates the PPTP VPN login and connection from the Connect window in RPS The VPN client or Windows V...

Страница 281: ...Panel List 7 To set panel parameters in the Panel List right click the panel account you clicked in step 1 then click Open Panel View 8 Panel Wide Parameters Cellular Plug in Module page 36 leave the parameters here at their defaults Only change for UL1610 commercial listed installations requiring low signal notification 9 Panel Wide Parameters Communicator overview page 58 Primary Destination Dev...

Страница 282: ...archy This includes the unique hostname of the device and the subnet on which the device is located separated by periods Example receiver01 your alarm company com Each label within the name must comply with RFC 921 Domain Name System Implementation Schedule Only the letters A Z numbers 0 9 and the minus sign are allowed in the text labels in the fully qualified domain name The period is only allow...

Страница 283: ......

Страница 284: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2017 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Отзывы: