Water Leak / Flood Detector
You can enable or disable monitoring for conditions of the connected passive water leak / flood
detector by means of the software utility S2000R Configurator as discussed in Section 7.
The water leak / flood detector occupies the polling loop address which follows the addresses of the
utility meters.
Mounting Location Considerations
The ASR2 should be installed closely to the connected meters.
Considering the mounting location for the S2000R-ASR2, please follow the instructions from Section
9 of this Manual.
Testing Link Quality
The Link Quality Test procedure is designed to estimate stability of radio link between the pulse
adapter and the ARR32 at their current locations and when obstructions exist on the path of radio
signals. You are recommended to carry out the Link Quality Test before the devices are attached at
their locations.
A Link Quality Test is started by a short press on the Prog button (see Figure 10-12). The procedure
takes 60 seconds, the detector being indicating the results of the test as shown in Table 10-28.
As testing link quality is in progress you can move the ASR2 and the ARR32 to find the best locations
for them.
You can also estimate quality of the link using S2000R Configurator as discussed in Section 7.
Updating Firmware
Mounting
Mount the S2000R-ASR2 to a clean flat vertical surface using double-sided tape provided.
The ASR2 should be programmed while operating in the 30-second poll mode. To switch
the ASR2 to this mode run S2000R Configurator (see Section 7) and press down the
tamper switch on the ASR2 PC board (see Figure 10-12) for a short time.
The small power supply in an S2000R-ASR2 after a long period of operation can fail to
support transmitting firmware over the radio channel.
Please change the S2000R-ASR battery for a fresh one prior to uploading
S2000R-ASR2 firmware