Addressable Radio Link System
www.bolid.ru
104
Table 10-58. Link Quality Indication
LED Performance
Condition
Flashes with green
Strong signal
Flashes with green and red
Normal signal
Flashes with red
Weak signal (not recommended to install)
Shows solid red light for 1 s
No communications or the device is not connected to
the ARR32
Table 10-59. S2000R-IK Rev.02 Test Indication
Event
LED Performance
Starting or finishing the test mode
Illuminates with amber for 1 s
Response of the IR sensor
Illuminates with red for 1 s
Getting Started
Open the detector case and remove the insulating spacer from the battery holder.
Connecting and Programming
Connect the detector to the ARR32 and set its parameters in the configuration of the polling loop
controller as discussed in Sections 6, 7, and 8 of this Manual.
The power save mode of the S2000R-IK rev.02 provides extending the battery life. In this mode the
PIR sensor turns off while being disarmed and turns on while being armed.
How to manage power save mode of the S2000R-IK rev.02 is described in Section 8.
Selecting operation mode of the S2000R-IK rev.02 provides preventing nuisance alarms by
detector’s disregarding the motion caused by animals weighting up to 10 kg (the Fine mode) or up to
20 kg (the Rough mode).
The detection accuracy of the detector can be selected by means of S2000R Configurator (see
Section 7).
Mounting Location Considerations
The detector is recommended to be installed at the height of 2.3 meters.
Considering the mounting location for the S2000R-IK rev.02, please follow:
To conserve battery life, it is recommended to disable indication in quiescent mode while
setting the detector parameters in the configuration of the polling loop controller in use