Indication
Table 10-27. S2000R-ASR2 Operation Indication
LED Performance
Condition
Flashes with red every 10 s
Alarm (open case)
Flashes with green every 10 s
OK
Flashes with amber every 10 s
Low battery
Three flashes with amber every 15 s
No communications with the ARR32
Table 10-28. Link Quality Indication
LED Performance
Condition
Flashes with green
Strong signal
Flashes with green and red
Normal signal
Flashes with red
Weak signal (not recommended to install)
Shows solid red light for 1 s
No communications or the device is not connected to
the ARR32
Getting Started
Open the device case and remove the insulating spacer from the battery holder.
Connecting and Programming
Connect the ASR2 to the ARR32 and set its parameters in the configuration of the polling loop
controller as discussed in Sections 6, 7, and 8 of this Manual.
The ASR2 can operate in three base operation modes. Depending on the operation mode it can
occupy one, two, or three addresses in the address space of the polling loop:
Two low pulse rate inputs (Input 1 and Input 2):
o
The first address for a meter 1;
o
The second address for a meter 2
Two low pulse rate inputs and a water leak / flood detector (Input 1, Input 2, Input 3):
o
The first address for a meter 1;
o
The second address for a meter 2;
o
The third address for the water leak / flood detector
High pulse rate input (Input 3)
o
The first address for a meter 1