S2000-2 S2000-2
Programming
77
www.bolid.com
ACCESS GROUP PARAMETERS
The significant part of access rules for each access key are specified by means of assigning this key
to a relevant access group number. Access rights and limitations defined for the access group are
extended to all the keys assigned to this group. Up to 32 different access groups can be described for
the S2000-2 controller. The parameters of an access group are listed in Table 9.
The
Access
attribute is set for an access group if the keys assigned with it are supposed to be used
for access.
The
Time Schedule
for access represents a number of time schedule defining intervals of time when
access can be granted for these keys. If this parameter is equal to 0, access is granted at any time.
Parameters of all other available 16 time schedules are programmable (see Time Schedules Section
of this Manual).
The
Antipassback Mode
and
Zonal Anti-passback Rule
define the controller’s reaction on the anti-
passback rule violation (see Anti-passback Rules Section of this Manual).
The Timed Anti-passback rule uses an additional
Anti-passback Lockout Period
parameter. During
this time period since key owner passing to an access zone the S2000-2 controller is operating as for
Hard Anti-passback rule and after expiration of the time the S2000-2 controller is operating as for Soft
Anti-passback rule.
Table 9. Access Group Parameters
Parameter
Function Description
Value Range
Access
Defines that keys assigned with the access group
configured are designed to gain access
On/Off
Time Schedule
(Access)
The number of a time schedule specifying the
time zones when the access is permitted for the
owners of keys included in the access group pro-
grammed
0…16
Anti-passback Mode
Defines the controller access policy in case of
anti-passback rule violation
None (not checked)
Hard
Timed
Soft
Anti-passback
Lockout Period
The period of time in HH:MM format used for the
Timed Anti-passback mode. Before this time expi-
ration since user passage to a zone is monitored
in accordance with Hard Anti-passback rules
while after expiration of this time in accordance
with Soft Anti-passback rules
0
Zonal Anti-passback
Rule
Specify to check anti-passback rules taking into
account passages between different zones of a
system (provides implementing of full entry/exit
control)
On/Off
Содержание S2000-2
Страница 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Страница 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 12: ...Orion ISS www bolid com 12 ...
Страница 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Страница 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Страница 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Страница 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Страница 94: ...Orion ISS www bolid com 94 ...
Страница 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...
Страница 100: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru www bolid com ...