Orion ISS
www.bolid.com
22
ACCESS MODES
In all the controller’s operation modes (
Two Entrance Doors
,
One Entrance/Exit Door
,
Turnstile
,
Swing-beam Barrier
, and
Two Sluice Doors
) each of the two readers connected to the controller can
operate in one of three following access modes:
−
Controlled Access Mode
−
Access Locked Mode
−
Free Pass Mode
If the access is locked (the Access Locked mode) an access can be granted only by the EXIT button
or by a remote network controller command.
In the Free Pass mode a door (turnstile, swing-beam barrier) is permanently open for free passing
(without identification and passage detection).
In the Free Pass or Access Locked modes the S2000-2 controller takes into account only special keys
(
Unlocking, Locking
or
Master
), as well as keys intended for loop and partition arming/disarming. Pre-
senting an
Unlocking
or
Locking
key restores the Controlled access mode – see Controlled Access
Mode Section below. Presenting a
Master
key to a reader switches the S2000-2 to the key program-
ming mode (local key programming
see Key Programming section of this Manual).
The access mode for one S2000-2 reader (access to one direction) can differ from the access mode
of another S2000-2 reader (access to another direction).
Access Locked Mode
Access can be locked for a reader by means of one of the following ways:
−
by a Locking key presenting to the reader (with the key time schedule and validity being
checked)
−
by the relevant command of the network controller, received via the RS-485 interface
−
by arming of an access locking alarm loop
Access Locked by a Locking Key or Network Controller Command
If access is locked by a
Locking
key or the remote network controller command, the LED of the rele-
vant reader begins flashing with red color (one flash per second with short pauses), the sounders of
the controller and the relevant reader, if enabled, playing four beeps.
In such a case an access is locked for all the keys stored in the controller memory (that is, local ac-
cess is locked). Only centralized access or access by pressing the EXIT button (if exists) is possible.
(Centralized access can be denied only by the network controller tools).
Содержание S2000-2
Страница 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Страница 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 12: ...Orion ISS www bolid com 12 ...
Страница 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Страница 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Страница 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Страница 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Страница 94: ...Orion ISS www bolid com 94 ...
Страница 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...
Страница 100: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru www bolid com ...