S2000-2
Operating
43
www.bolid.com
Condition/Event Lighting
Mode
Color
Centralized partition control, the partition is
armed
On
Yellow
(Red + Green)
Centralized partition control, the partition is dis-
armed
Off –
Centralized partition control, an alarm within the
partition
Flashes twice per second
Yellow
(Red + Green)
The pause after a car has passed before the
swing-beam barrier is lowered down
Flashes twice per second
Red
The door is expected to be closed after entering
or exiting the sluice
Flashes 5 times per second
Red
Programming access keys
Flashes with red and green
alternately twice per second
Red/Green
alternately
Programming a Master key
Double flashes with red and
green alternately
Twice
red/Twice
green
* – the condition is indicated only if this loop’s alarm indication is permitted for this reader
Table 4 C2000-2 Sounder and Reader Sound Signaling
Condition/Event Category Sound
Signaling
Quiescent mode
–
Off
Access is granted
Access
Two beeps
Access is denied
Access
Long sound (Error)
A main code is recognized under two
factor authentication condition
Access A
beep
A first key is presented under two-person
rule access condition
Access A
beep
For the Turnstile, Swing-beam Barrier,
and Two Sluice Doors operating modes,
while requesting the access to one direc-
tion a key for the access to another direc-
tion is presented
Access
Two short and one long sounds
(‘Please wait’)
Access is opened by a special key
Access
Short + 2 short + 2 short sounds (‘Access
is opened’)
Access is locked by a special key
Access
Long + 4 short signals (‘Access is
locked’)
Controlled access mode recovery by a
special key
Access
2 short + 2 short + short sounds (‘Access
is controlled’)
Содержание S2000-2
Страница 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Страница 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 12: ...Orion ISS www bolid com 12 ...
Страница 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Страница 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Страница 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Страница 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Страница 94: ...Orion ISS www bolid com 94 ...
Страница 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...
Страница 100: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru www bolid com ...