S2000-2 S2000-2
Programming
83
www.bolid.com
KEY PROGRAMMING
If the S2000-2 controller operates as a part of a PC-based Orion system, codes of iButtons, Proximity-
cards and other identifiers are saved to the S2000-2 database (into the controller non-volatile mem-
ory) with the help of the
Orion Database Administrator
utility
of the Orion Workstation
software.
If the S2000-2 controller operates as a part of an Orion system based on the S2000/S2000
М
control
console or the S2000-2 operates standalone, access keys are programmed by means of UProg Con-
figuration Tool software (
uprog.exe
) installed on a personal computer (PC). This software facilitates
adding and deleting keys, setting and modifying key attributes, saving the list of programmed keys to
a file, loading a key list from a file to the controller memory, etc.
Moreover, the keys can be programmed by hardware without PC, with the help of one or more Master
keys. Any identifier can be used as a Master key if the Master key type is set for it. Presenting Master
key turns on the key programming mode. New keys presented to one of the controller readers in this
mode are enrolled to the controller memory with User type, inherit access group of the Master key
and have unlimited validity.
Also a single Master key with access group #0 can be programmed by hardware only, without PC. To
do this remove the cover of the controller enclosure and then press the tamper switch for three times.
First pressing has to be prolonged (longer than 1.5s), the second one has to be short (less then 0.5s),
and the last one has to be prolonged again. Pauses between pressings should not exceed 0.5s. The
sounders of the controller and the first reader will play special ‘
Master Programming
’ melody, the
READY indicator and the LED of the first reader will start double flashing synchronously, the LED of
the reader double flashing with red and green color alternately. If the first reader is busy (the last ac-
cess procedure has not yet been finished), the Master key programming mode indication will be acti-
vated on the second reader. After that the key to be programmed has to be presented to those reader
which indicates Master programming mode, within 30s after the mode being switched to. Sounders of
the controller and the reader will play ending of the ‘Master Programming’ melody and the READY
indicator and reader LED will start to light continuously.
WARNING!
Programming the Master key with a tamper switch deletes all the previously pro-
grammed keys that are stored in the controller memory
(while Master keys programming by
means of the uprog.exe software has no effect on previously programmed keys).
Master keys of other (non-zero) access groups have to be preliminary programmed using the
uprog.exe software.
To enter the hardware key programming mode for User key programming, it is necessary to present a
Master key to one of the controller readers. Three pairs of short sound signals will be generated by
the sounders of the reader and the controller, and the LED of this reader will flash alternately with red
and green colors. In this mode the presented identifiers are saved to the controller memory and as-
signed with access group number of the Master key. If a new key code is successfully stored in the
Содержание S2000-2
Страница 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Страница 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 12: ...Orion ISS www bolid com 12 ...
Страница 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Страница 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Страница 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Страница 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Страница 94: ...Orion ISS www bolid com 94 ...
Страница 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...
Страница 100: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru www bolid com ...