Orion ISS
www.bolid.com
70
ceiving a code of the card from any reader the controller will set the high-order bits (from 25 to 48) of
the card code to 0, and the code will be the same regardless of the type of the reader.
Decreasing the
Key Serial Number Length
value (to less than 48 bits) can be used while importing a
key database from any other system to an Orion system in the case if the keys were stored with
shortened serial numbers. In such the case the
Key Serial Number
Length
is to be selected accord-
ing to the quantity of known digits of the key serial numbers.
If no one of the reviewed tasks is set, it is not advisable to modify the
Key Serial Number
parameter
(let it be 48 bit on default).
If this parameter is being modified for the controller which stores some previously entered keys in its
memory the UProg Configuration Tool generates a prompt asking the permission to correct existing
key codes (set high-order bits to zeros and recount the keys’ CRC). This action is irreversible, i.e. if
the
Key Serial Number Length
will be increased afterwards the key is to be newly entered into the
controller (for example, to be loaded from the previously saved file).
All controller sound alarms fall into four categories:
Access, Door Forced/Held Open, Loop Alarms
and Programming
(see Table 6). Activating of the controller’s sounder at any event is defined by
relevant sound alarm configuration settings.
READER CONFIGURATION PARAMETERS
Both readers of the controller have similar sets of the configuration parameters given in Table 7.
Table 7. Reader Configuration Parameters
Parameter Description Range
Factory
Value
Output Interface
The way to transmit the read
code of the presented key to the
S2000-2
1 Touch Memory
2 Wiegand
3 ABA TRACK II
1
(Touch
Memory)
Time to Hold Keys for
Arming/Disarming
Time needed the combined key
to be held at the reader in order
to arm/disarm alarm loops (for
Touch Memory output interface
readers only)
0…32 s
0
(off)
Access Zone Number
The number of the access zone
passing to which is controlled by
means of the reader
0…65535
(65535 means
an undefined zone)
65535
Two Factor
Authentication
The mode of identification when
each key involves codes of two
different types (for combined
readers only)
On/Off Off
Passage Sensor
A sensor detecting door open-
ing, passing or car presence, is
connected and used for an ac-
cess strategy
On/Off Off
Содержание S2000-2
Страница 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Страница 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 12: ...Orion ISS www bolid com 12 ...
Страница 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Страница 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Страница 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Страница 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Страница 94: ...Orion ISS www bolid com 94 ...
Страница 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...
Страница 100: ...4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 513 32 35 Email info bolid ru www bolid com ...