13
5.3
Switch on the machine
Before switching on the blast machine, switch on the dustcollector 200DC.
If the underpressure is OK, indicator (#8) will light up green.
Lift the machine a little bit above the ground and allow it to suck to the wall.
The WALL SENSOR OK indicator (#7) will light up green.
Press the green
button “
START Blastmotor
” and check the rotating direction of the blast motor. The
correct direction is given with an arrow on the housing of the motor.
Keep a safe distance behind the blast machine.
Move the machine 1 meter up and down to make sure everything is OK.
Move the machine up again and when the machine is traveling, open the shot valve (#10). Observe
the ammeter on the display.
Maximum blast wheel amperage = 14.5 Ampere.
Adjust the load
amperage by opening or closing the shot valve. After having blasted approximately 2 meter, close the
shot valve(#9), stop the machine (#2) and check the blasted surface.
If the ‘hotspot’ must move to the right, turn the cage a little bit to the right.
Never adjust the cage
during blasting
! Loosen the nuts (#11) of the window indicator and adjust the position to the right.
Tighten the nuts after adjusting.
If the ‘hotspot’ must move to the left, adjust the window indicator to the left.
1
2
3
4
5
Emergency
stop
button
STOP
Blastmotor
START
Blastmotor
Connection
for control
cable
Ampere-
meter /
ammeter
6
7
8
9
10
Warning
light
MOTOR
FAILURE
Indicator
WALL
SENSOR
OK
Indicator
PRESSURE
OK
CLOSE
Shotvalve
button
OPEN
Shotvalve
button
1
4
5
6
7
8
9
1
0
3
2
1
1
Содержание 200VMB
Страница 1: ...Original instructions in English OPERATING INSTRUCTIONS 200VMB VERSION 1 2...
Страница 22: ...22 2 Use a brass drift to tap out the side liners...
Страница 23: ...23...