Specify a label for the port.
Select the appropriate
Baud Rate
,
Parity
,
Data Bits
,
Stop Bits,
and
Flow Control
for each port.
(Note: The RS-‐485/RS-‐422 option is not relevant for
console server
s.)
Before proceeding with further serial port configuration, connect the ports to the serial devices
they will be controlling, and make sure they have matching settings.
Note
The serial ports are all set at the factory to RS232 9600 baud, no parity, 8 data bits, 1 stop bit,
and
Console server
Mode. You can change the baud rate to 2400–230400 baud using the
management console. You can configure lower baud rates (50, 75, 110, 134, 150, 200, 300, 600,
1200, 1800 baud) from the command line. Refer to
Chapter 14— Basic Configuration (Linux
Commands).
4.1.2 Console Server Mode
Select
Console Server Mode
to enable remote management access to the serial console that is attached
to this serial port: