![background image](http://html.mh-extra.com/html/biocare/im-12/im-12_user-manual_2753377101.webp)
Chapter 6 Parameter Monitoring
User Manual of Veterinary Monitor
--89--
Warning
Anesthetic: the sidestream CO
2
module, to measure the use of anesthetics or recently used
anesthetic animals, the vent on the module must be connected to the exhaust gas treatment system,
anesthesia machine or ventilator, to avoid medical personnel inhalation anesthetic.
6.9 C.O. (Optional)
6.9.1 General Description
Warning
C.O. monitoring is restricted to animals > 20 kg only.
The cardiac output (C.O.) function invasively measures cardiac output and other hemodynamic parameters by
using the thermodilution method. A cold solution of known volume and temperature is injected into the right
atrium through the proximal port of a pulmonary artery (PA) catheter. The cold injectable solution mixes with the
blood in the right ventricle and the change in blood temperature is measured with a thermistor at the distal end of
the catheter in the pulmonary artery. The C.O. Cable Socket is shown as follows:
6.9.2 Influencing Factors of Measurement
temperature of injectable solution
volume of injectable solution
animal‘s baseline blood temperature
animal‘s inspiratory/expiratory cycle
the extent of proximity of the distal end of catheter and the lung
the PA catheter itself
the animal heart rate and hemodynamic status
any other rapid IV solutions which are injected while the C.O. measurement is being performed
C.O. Cable Socket
Содержание iM 12
Страница 2: ......
Страница 12: ...Content VIII User Manual of Veterinary Monitor The Blank Page ...
Страница 14: ...Preface 2 User Manual of Veterinary Monitor The Blank Page ...
Страница 22: ...Chapter 1 Operation Safety Information 10 User Manual of Veterinary Monitor The Blank Page ...
Страница 44: ...Chapter 3 Basic Operation 32 User Manual of Veterinary Monitor The Blank Page ...
Страница 54: ...Chapter 5 User Interface 42 User Manual of Veterinary Monitor The Blank Page ...
Страница 134: ...Chapter 8 Freeze and Review 122 User Manual of Veterinary Monitor The Blank Page ...
Страница 142: ...Chapter 10 Recording 130 User Manual of Veterinary Monitor The Blank Page ...
Страница 154: ...Chapter 14 Maintenance 142 User Manual of Veterinary Monitor The Blank Page ...
Страница 180: ...Appendix C Alarm Information 168 User Manual of Veterinary Monitor The Blank Page ...
Страница 194: ...Appendix E EMC Guidance and Manufacture s Declaration 182 User Manual of Veterinary Monitor The Blank Page ...
Страница 195: ......