KB ECO / KB ECO-UL (E6.2) 12/2021
Page 69/85
26.4 KB ECO / KB ECO-UL technical data
Chamber size
240
720
1020
Exterior dimensions
Width, gross (incl. access port)
mm /
inch
932/
36.69
1255 /
49.37
1254 /
49.37
Height, gross (incl. feet/castors)
mm /
inch
1461 /
57.52
1925 /
75.79
1925 /
75.79
Depth, net
mm /
inch
796 /
31.34
885 /
34.84
1149 /
45.24
Depth, gross (including door handle, I-triangle, con-
nection and 30 mm for cable)
mm /
inch
921 /
36.26
1013 /
39.88
1277 /
50.28
Wall clearance rear (minimum)
(spacer)
mm /
inch
100 /
3.94
100 /
3.94
100 /
3.94
Wall clearance side (minimum)
mm /
inch
180 / 7
.09
180 / 7
.09
180 / 7
.09
Doors
Quantity of doors
1
2
2
Quantity of glass doors
1
2
2
Interior dimensions
Width
mm /
inch
650 /
25.60
970 /
38.19
970 /
38.19
Height
mm /
inch
785 /
30.91
1250 /
49.21
1250 /
49.21
Depth
mm /
inch
485 /
19.09
576 /
22.68
836 /
32.91
Interior volume
l /
cu.ft.
247 /
8.7
700/
24.7
1020 /
36.0
Steam space volume
l /
cu.ft.
348 /
12.3
918 /
32.4
1280 /
45.2
Racks
Quantity of racks (regular)
2
2
2
Quantity of racks (max.)
9
15
15
Maximum load per rack
kg /
lbs.
30 /
66
45 /
99
45 /
99
Maximum permitted total load
kg /
lbs.
100 /
220
150 /
331
150 /
331
Weight
Weight (empty)
kg /
lbs.
152 /
335
272 /
600
327 /
721
Temperature data
Temperature range
from … degrees below
ambient temperature
°C /
°F
28 /
50.4
26 /
46.8
26 /
46.8
up to °C /
°F
70 /
158
70 /
158
70 /
158
Temperature fluctuation
at 25 °C /
77 °F
± K
0.1
0.1
0.1
at 37 °C /
98.6 °F
± K
0.1
0.1
0.1
Temperature
uniformity (variation)
at 25 °C /
77 °F
± K
0.1
0.1
0.1
at 37 °C /
98.6 °F
± K
0.1
0.1
0.1
Recovery time after one
door was open for 30 s
at 25 °C /
77 °F
minutes
1
1
1
at 37 °C /
98.6 °F
minutes
4
4
3
Max. heat compensation
at 40 °C /
104 °F
W
350
500
500
Electrical data
(model versions KBECO240-230V, KBECO720-230V, KBECO1020-230V)
System of protection acc. to EN 60529
IP
20
20
20
Nominal voltage (+/-10%)
at 50 Hz power frequency
V
200-230
200-230
200-230
at 60 Hz power frequency
V
200-230
200-230
200-230
Current type
1N~
1N~
1N~
1N~
Power plug
CEE 7/7 grounded plug
Nominal power
kW
0.90
1.30
1.30
Installation category acc. to IEC 61010-1
II
II
II
Pollution degree acc. to IEC 61010-1
2
2
2
Over-current release category B, 2 poles
Amp
16 internal 16 internal 16 internal
Содержание 9020-0423
Страница 72: ...KB ECO KB ECO UL E6 2 12 2021 Page 72 85 26 7 Dimensions Dimensions size 240 mm...
Страница 73: ...KB ECO KB ECO UL E6 2 12 2021 Page 73 85 Dimensions size 720 mm...
Страница 74: ...KB ECO KB ECO UL E6 2 12 2021 Page 74 85 Dimensions size 1020 mm...
Страница 76: ...KB ECO KB ECO UL E6 2 12 2021 Page 76 85...
Страница 77: ...KB ECO KB ECO UL E6 2 12 2021 Page 77 85...
Страница 79: ...KB ECO KB ECO UL E6 2 12 2021 Page 79 85...