55
DD1010 FLYNET
5.2.2
Serial Ports
From this page it is possible to set the serial transmission parameters of the COM ports.
The COM ports that are always physically present are: COM4, COM6 and COM7.
If an optional serial expansion board is installed the COM ports are: COM8 and COM9.
Instead a possible USB/Serial port converter uses COM higher than 10.
Always save the configuration before exiting if some parameters have been changed.
The editable features for each COM are:
baud rate
4800
9600
19200
38400
115200
Bits
7
8
Stop bits
1
2
Parity
No
Even
Odd
Handshake
No
Hardware
Xon/Xoff
Protocol
RS232 (on: COM4 and COM6)
RS422 (on: COM7)
RS485 (on: COM7)
5.2.3
Printers/Readers/IOs
Press the "Printers/Readers/IOs"
key to access the settings area of the following
components:
System
Axis
manage
ment
Strictly related to the activation of the service. It cannot be used if the axis
management service has not been activated from the relevant menu.
For configuration, follow the instructions in chapter 5.2.3.1
System
Service that checks the internal memory use and signals when the set