24
DD1010 FLYNET
3.3.1
Wiring diagram (with platform)
Figure 3.3-1 - Connecting the indicator to the scale
Key:
1. Weight display indicator.
2. Weighing platform or weighbridge.
3. Scale cable with 9/15 pin connector.
4. Scale input.
5. Equipotential cable with eyelet wire terminals.
6. Ground screw.
7. Ground screw on the platform.
8. Ground poles (for weighbridge only).
3.3.2
Equipotential between indicator and weighing platform
Check that there is equipotential between the metal parts of the indicator and the weighing platform.
If in doubt, connect indicator and platform with a ground cable of at least 6mm², using the ground
screw on the bottom of the indicator.
The cables and accessories for this connection are not included in the supply but are the
responsibility of the customer.
1
2
3
4
5
6
7
8
Содержание DD1010
Страница 2: ......