9
DD1010 FLYNET
1.7
Technical characteristics of the indicator
Power supply
Direct
12 Vdc/3 A (Min 11 V - Max 15 V)
Via network adapter
L+N+R
110 - 240 Vac (-15% ... +10%)
1.8 A
50 - 60 Hz
60W Max
Ground socket
Equipotential for weighbridge
Scales
Total
1/2
(or 1 analogue, or 1 digital, or 2 analogue or 2
digital)
Repeater operation
Analogue scale
Connectable cells
Up to 12 x 350 ohm analogue cells per scale
Minimum impedance
29 ohm per scale
Load cell power supply
4.5-5 Vdc
Internal resolution
1000000 points at 10 Hz
Resolution in type-approved version
1 range of 6000
Maximum input signal
35 mV
Sensitivity
0.6 µV/division
Full scale stability
< 5 ppm/°C
Zero stability
< 5 ppm/°C
Digital scale
Connectable cells
Up to
a scale with 16 digital cells or two scales
with 8 digital cells each
Load cell power supply
8 to 15 Vdc
Internal resolution
200000 points @ 25 conv/s
Resolution in type-approved version
1 range of 6000
Environmental characteristics
Compensated temperature range
-10 to + 40 °C
Operating range
-10 to + 40 °C
Maximum humidity
85% @ 40 °C
IP protection rating
Plastic version and stainless steel version with
connectors: direct outputs IP 20 and front IP 65.
Stainless steel version with cable glands IP 69K
User interface
Video
5.
7” LED TFT display
Keyboard
Touch screen