112
DD1010 FLYNET
10.6.3 Stainless steel version with cable glands
WARNING
If the time and date are missing when the indicator is switched on, the lithium battery must be
replaced.
Figure 10.6-3 - Disassembling lithium battery
Referring to the previous figure, proceed as follows:
Switch the indicator off and disconnect it from the electrical mains.
Open the indicator.
Remove the indicator power supply unit.
Remove the power supply unit for scale.
Remove the lithium battery (ref. 1) being careful not to cause short circuits.
ATTENTION
Take special care to avoid dropping the battery on the motherboard, as it may damage some
parts of the motherboard or the entire card.
Replace with a battery identical to the one removed from the equipment (model CR2450).
ATTENTION
Dispose of the battery via separate waste collection either handing it over to the distributor or to
separate waste collection centres.