D812034 00100_01
22
- VISTA SW SXL -VISTA SW MXL
INSTALLATION MANUAL
12) OPERATING PARAMETER MANAGEMENT - DISPLAY
PARAMETER
DEFINITION
MIN.
MAX.
DEFAULT
CUSTOM
DESCRIPTION
01
Opening speed [°/s]
20
70
60
Motor speed during opening
02
Closing speed [°/s]
10
40
20
Motor speed during closing
03
TCA [s]
0
60
0
Waiting time before automatic closing.
04
Disabled hold time [s]
5
60
5
Waiting time before automatic closing using the disabled opening
command or in Low Energy mode
05
VISTA SW SXL:
Spring-operated
closing speed
1
9
0
Spring-operated closing speed (1=minimum speed, 9=maximum speed)
VISTA SW MXL:
Wind protection with
door closed
0
9
0
Sets wind protection strength with door closed
(0=wind protection disabled, 9=max. wind protection)
06
Opening force and
Closing force
1
9
5
Force exerted by leaf during opening and closing before obstacle alarm is
generated. (1=most sensitive; 9=least sensitive)
07
Acceleration and
Deceleration
5
30
30
Acceleration and deceleration speed
08
Approach angle
10
40
20
Adjusts approach angle (closing is 1/2 of opening)
09
Solenoid lock voltage
0
1
0
1 = 12Vdc solenoid lock output
2 = 24Vdc solenoid lock output
10
Solenoid lock type
0
5
0
0 = Not used
1 = Pulse mode with relock when door closes again
2 = Standard magnetic
3 = Fail-safe magnetic
4 = Motorized
5 = Pulse mode with relock when power is cut off
11
Solenoid lock
management time
Opening delay after lock
release
0
9
2
The time depends on the solenoid lock type:
- Pulse mode with relock when door closes again 50-500 ms
- Magnetic & Fail-safe 200 to 2000 ms
- Motorized 500 to 5000 ms
- Pulse mode with relock when power is cut off 100-1000 ms
12
Closing limit switch
pressure
0
9
5
Force exerted by the leaf to allow lock to engage
13
Single/Master/Slave
0
2
0
0 = Single board
1 = Board connected as Master
2 = Board connected as Slave
14
Door locked closed with
motor and lock
0
3
3
0 = Disabled
1 = Enabled with “Internal radar” mode
2 = Enabled with “Standard radar” mode
3 = Enabled with “Internal radar” and “Standard radar” mode
15
Auxiliary input 1
confi guration
0
6
0
0 = Input confi gured as Disabled opening
1 = Input confi gured as Emergency opening
2 = Input confi gured as Interlock door with priority
3 = Input confi gured as Interlock door without priority
4 = Input confi gured as Lock Release Feedback
5 = Input confi gured as Lock release
6 = Input confi gured as Single Command with Master/Slave operating mode
7 = Input confi gured as Standby. If activated, it sets the door to standby only
with the door in the closed position.
8 = Input confi gured as wake up from Standby. If activated, it restores
operation following a Standby
9 = Input confi gured as step-by-step command, meaning that with a pulse
the door opens and stays open, standing by for another pulse to close, again
with the use of Int. Radar or Ext. Radar
https://appceso.com