D812034 00100_01
20
- VISTA SW SXL -VISTA SW MXL
INSTALLATION MANUAL
1) GENERAL INFORMATION
Motorized header for automatic swing doors, complete with control panel. Ac-
cessories available for producing a complete installation.
2) TECHNICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Leaf width
min. 700mm max. 1400mm
Leaf weight
see fi g. S
Opening speed
max. 70°/s - min. 20°/s (3 - 6 sec.)
Closing speed
max. 74°/s - min. 10°/s (4 - 15 sec.)
Max. opening angle
110°
Header size
See Fig. B
Actuator weight
11 kg
ELECTRICAL SPECIFICATIONS
Power supply
220 - 230V~ ±10%, 50/60 Hz single phase
Fuses
see Fig. G
Accessories power supply
15Vdc - max. 12W
Rated power
85W
Temperature range
from -10°C to + 50°C (inside cover)
Operating cycle
Continuous at 25°C
Anti-crush
Anti-crush safety device when
obstacles are detected
Backup batteries
(optional extras) 2 x 12V 1.2Ah
Protection rating
IP 40
3) PREPARING THE ELECTRICAL SYSTEM
Prepare the electrical system (Fig. A), referring to the standards in force. Keep
mains power connections well separated from service connections (photocells,
safety edges, control devices, etc.). Keep mains power connections well separated
from safety extra low voltage connections.
4) IDENTIFICATION OF PARTS
Fig. R
The VISTA SW automatic door operator comprises:
1. Load-bearing aluminium header
2. Power supply unit
3. Microprocessor-based control unit
4. DC
gearbox
5. End panel on power unit end
6. End panel on gearmotor end
7. Anodized aluminium cover
The following optional accessories are available to complete installation:
8. BBV SW MXL backup batteries kit for VISTA SW MXL only
9. VISTA SEL SW Digital function control station
10. EXT ASW XL 30-50-70-90 arm attachment fi ttings
11. TSWP XL PROFILES for VISTA SW IN PAIR (see FIG. V)
5) FASTENING METHOD
-
Dismantling the parts Fig. 1
-
Fastening the load-bearing header Fig. 2
-
Cable routing Fig. B
-
Reassembling the parts Fig. 1
7) INSTALLATION OPTIONS
Fig. C
- With SLIDE ARM, pull option; use when automatic door operator is installed
on the pull side).
- With DOUBLE LEVER ARM, push option; use when automatic door operator
is installed on the push side).
7.1) INSTALLING THE SLIDE ARM
Fig. D
- Fasten the guide on the door leaf Fig. D1
- Assemble the guide Fig. D2
- Adjust the spring to level 4 (for VISTA SW SXL only) Fig. D3
- With the door closed, insert the arm in the automatic door operator’s shaft,
lining up the other end with the slide’s axis Fig. D4
- Remove the arm, slide out the arm attachment fi tting, rotate it by 1 or 2 teeth
in the direction the door closes (Fig. D5) and fi t it back in the shaft (for VISTA
SW SXL only)
- Fasten the arm (Fig. D6)
7.2) INSTALLING THE DOUBLE LEVER ARM
Fig. E
- Fasten the arm to the leaf (Fig. E1
- Adjust the spring to level 4 (for VISTA SW SXL only) Fig. E2
- Assemble the arm and fasten it to the actuator’s output shaft Fig. E3
- Loosen screws V3, position the main arm correctly at a 90° angle to the door
(Fig. E4), rotate the main arm so that the two arms sit at the same angle to the
door Fig. E4, then fasten screws V3.
8
) SPRING ADJUSTMENT (for VISTA SW SXL only)
Fig. F
Spring power must be adjusted based on the width of the DOOR leaves and
taking into consideration the power sizes according to standard EN 1154, in the
range from 4 to 6.
9) CONTROL PANEL
9.1) CONNECTIONS
Fig. G, L, M
WARNINGS - When performing wiring and installation, refer to the standards
in force and, whatever the case, apply good practice principles.
The wires carrying a very low safe voltage (24V) must be kept physically separate
from low-voltage wires, or they must be suitably insulated with at least 1mm of
additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
Terminal
Defi nition
Description
L
Line
Single-phase power supply 220-
230V~ 50/60 Hz
Earth
N
Neutral
Key
Locking signal (NC)
Locking signal. If the contact
opens, the control unit commands
the leaves to close completely.
The signal must be connected
with COM if there are no devices
connected.
RADAR EXT
EXT RADAR input (NO)
Opening signal. If this contact
closes, the leaves are opened.
RADAR INT
INT RADAR input (NO)
Opening signal. If this contact
closes, the leaves are opened.
PHOT OP
OPENING PHOTOCELL
input (NC)
Opening safety signal. If the door
is opening and the contact opens,
the control unit commands the
door to stop moving immediately.
The signal must be connected
with COM if there are no devices
connected.
PHOT CL
CLOSING PHOTOCELL
input (NC)
Closing safety signal. If the door is
closing and the contact opens, the
control unit commands the door
to reverse immediately. The signal
must be connected with COM if
there are no (internal or external)
devices connected.
COM
Commands common
AUX IN 1/2
Auxiliary inputs
confi gurable
This signal can be set to any of
the confi guration options given
for parameters 15 and 16, see
the OPERATING PARAMETER
MANAGEMENT-DISPLAY table
AUX OUT 1/2
Auxiliary outputs
confi gurable
This signal can be set to any of
the confi guration options given
for parameters 17 and 18, see
the OPERATING PARAMETER
MANAGEMENT-DISPLAY table
OUT 15 VDC
Peripheral unit power
supply
15Vdc output max. 12W
RST
Serial connection for
Master/Slave connection
and selector
PWF
DATA
GND
LOCK
Solenoid lock output
12 and 24 VDC solenoid lock output,
see OPERATING PARAMETER
MANAGEMENT-DISPLAY table,
parameter 09, max. 15W