D812034 00100_01
18
- VISTA SW SXL -VISTA SW MXL
Diagnostics and warnings
Warnings
Descriptions
OP
Steady
Door Open
OP
Flashing
Door opening
CL
Steady
Door closed
CL
Flashing
Door closing
E1
System parameter initialization fail (self-learning) error. Run Autoset procedure again, LP menu
E2
Selection error for automatic door operator type (Dip switch 5) or arm type (Dip switch 1 or arm setting on passive brake board)
E3/E4
Maximum current threshold exceeded error (OVERCURRENT)
E6
Supervised sensor initialization fail error. Run the LS supervised sensor automatic acquisition procedure again
E8
No encoder connection error
SO
Steady
no supervised sensor detected.
S1
Steady
supervised sensor detected during opening, on Phot Op input.
S1
Flashing
failed safety test on sensor during opening.
S2
Steady
supervised sensor detected during closing, on Phot Cl input.
S1
Flashing
failed safety test on sensor during closing.
S3
Steady
supervised sensors detected during opening and closing, on Phot Op and Phot Cl inputs.
S3
Flashing
failed safety tests on sensors during opening and closing.
ST
Stop. The door stopped during opening due to a safety device being triggered