D812034 00100_01
24
- VISTA SW SXL -VISTA SW MXL
INSTALLATION MANUAL
PARAMETER
DEFINITION
MIN.
MAX.
DEFAULT
CUSTOM
DESCRIPTION
29
AUX-IN 2 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
30
AUX-OUT 1 input
polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
31
AUX-OUT 2 input
polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
32
Force during reset
0
9
5
Adjusts motor force at time for fi rst operation following reset (0 = least force,
9 = most force)
33
Opening angle
reduction percentage
level [%]
0
50
0
During normal operation, swing will be smaller than the angle detected
during the stops
acquisition procedure so as to allow operation when there is no mechanical
stop.
34
Assembly on lintel or on
door leaf
0
1
0
0 = Motor installed on lintel
1 = Motor installed on door leaf
TS
Test
0
2
0
0 = Normal operation
1 = Cyclic testing, automatic opening and closing
2 = Intensive cyclic testing, automatic opening and closing
SD
Default
/
Restores all parameters to default values and resets the acquired travel.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key
LP
Autoset
/
Travel acquisition.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key.
LS
Acquisition of
supervised sensors
Acquisition of connected supervised sensors.
Procedure:
1-Select command with [+] and [-] keys;
2-Press [ENT];
3-When display reads [--], hold [ENT] down for 5 seconds to validate;
4-When [--] disappears, release the [ENT] key.
5-When acquisition is done, confi rm sensors detected with [ENT] or press
[ESC] to cancel.
13 ) DOOR OPERATING MODE (With VISTA SEL or logic selection switch)
Fig. O
EXTERNAL RADAR:
Only the RADAR EXT input on the control circuit board is
monitored.
A signal from a sensor connected to this input causes the door leaf to open and
consequently close.
The solenoid lock, where fi tted, locks the door leaf whenever it reaches the fully
closed position.
INTERNAL RADAR:
Only the RADAR INT input on the control circuit board is
monitored.
A signal from a sensor connected to this input causes the door leaf to open and
consequently close.
The solenoid lock, where fi tted, locks the door leaf whenever it reaches the fully
closed position.
RADAR IN STANDARD MODE:
Both RADAR EXT and RADAR INT inputs on the
control circuit board are monitored. A signal from a sensor connected to one of
these inputs causes the door leaf to open and consequently close.
The solenoid lock, where fi tted, locks the door leaf whenever it reaches the fully
closed position.
DOOR CLOSED BY DAY:
The door is locked in closed state. Panic feature, if
enabled, is on.
The automatic door operator commands the door leaf to close fully. With this logic
selected, the RADAR EXT and RADAR INT inputs on the control circuit board are
not monitored; the solenoid lock, where fi tted, locks the door leaf.
DOOR CLOSED AT NIGHT:
The door is locked in closed state. Panic feature, if
enabled, is off .
The automatic door operator commands the door leaf to close fully. With this logic
selected, the RADAR EXT and RADAR INT inputs on the control circuit board are
not monitored; the solenoid lock, where fi tted, locks the door leaf.
DOOR TOTAL OPEN:
The door is locked in open state.The automatic door operator
commands the door leaf to open fully. With this logic selected, the RADAR EXT
and RADAR INT inputs on the control circuit board are not monitored;
MANUALLY OPENED DOOR:
With this logic selected, the RADAR EXT and RADAR
INT inputs are disabled. The door is opened and closed manually. The opening
safety sensor and closing safety sensor are only active in the event of motor-driven
opening for the disabled.