INSTALLATION MANUAL
Terminal
Definition
Description
Po
w
er
supply
L
LINE
Single-phase power supply
N
NEUTRAL
M
ot
or
10
START + CONDENSER
Motor and condenser connection
11
COM
12
START + CONDENSER
Au
x
20
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
Exit due to FLASHINg LIgHT
Contact stays closed while leaves are operating.
21
Limit
swit
ches
41
+REF SWE
Limit switch common
42
SWC
Closing limit switch SWC (N.C.)
43
SWO
Opening limit switch SWO (N.C.)
A
cc
essories
po
w
er supply
50
0V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
Commands
60
Common
START and OPEN inputs common
61
START
SHYRA AC SL
START command button (N.O.).
Operation according to “Residential / apartment building operation” logic
SHYRA AC BA
If trimmer T2 at maximum:
START command button (N.O.).
Operation according to “Residential / apartment building operation” logic
If trimmer T2 at minimum:
CLOSE command button (N.O.).
The command causes the device to close. If the input stays closed, the leaves stay open until
the contact is opened.
62
OPEN
OPEN command button (N.O.).
gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
TABLE ERR
Led ERR
Lit
slow flashing
fast flashing
Led SE
T
Unlit
Photocell test,
Costa o Costa 8k2 failed
- Check photocell connection and/or logic
settings
Lit
Reverse due to
obstacle - Amperostop
- Check for obstacles in path
Thermal cutout
- Allow automated device to cool
slow
flashing
Internal system supervision control error.
- Try turning the board off and back on or
press button S2. If the problem persists, con-
tact the technical assistance department.
Thermal cutout
- Allow automated device to cool
Changed settings and/or Operating logics
press S2 for 5s to confirm.
22 -
SHYRA