DIP
Logic
Default
Cross out
setting used
Description
5
Photocells
during closing
OFF
ON
In the event beam is broken, photocell operation is disabled during opening. During closing, move-
ment is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
6
Safety edge
input operation
OFF
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
Safety edge with active reversal in both directions
7
Fast closing
OFF
ON
SHYRA AC SL
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
SHYRA AC BA
Closes 1 second after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Logic not enabled
8
Residential /
apartment
building
operation
OFF
ON
Sets the
automation type
of operation:
ON = Apartment building
Reaction to the START input (wired or radio):
Residential
Apartment building
CLOSED
Opens
Opens
WHILE CLOSINg
Stops
Opens
OPEN
Closes
Closes
WHILE OPENINg
STOPS + TCA
No effect
AFTER STOP
Opens
Opens
Reaction to the OPEN input (wired):
Residential
Apartment building
CLOSED
Opens
Opens
WHILE CLOSINg
Opens
Opens
OPEN
No effect
No effect
WHILE OPENINg
Keeps it open
Keeps it open
AFTER STOP
Opens
Opens
Reaction to the PEDESTRIAN input (radio):
Residential
Apartment building
CLOSED
Opens partially
Opens partially
WHILE CLOSINg
Stops
Opens partially
OPEN
Closes
Closes
WHILE OPENINg
STOPS + TCA
No effect
AFTER STOP
Opens partially
Opens partially
OFF
OFF = Residential
INSTALLATION MANUAL
24 -
SHYRA
D812090 00100_04