ENGLISH
INSTALLATION MANUAL
Terminal
Definition
Description
Saf
et
y de
vic
es
70
Common
STOP, PHOT and BAR inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
PHOT (*)
PHOTOCELL input (N.C.).
Operation according to “PHOTOCELL/PHOTOCELL DURINg CLOSINg” logic. If not used, leave
jumper inserted.
73
FAULT 1
Test input for safety devices connected to PHOT.
74
BAR /
BAR CL /
BAR TEST /
BAR CL TEST /
BAR 8K2 /
BAR CL 8K2
(*)
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
Safety edge
check
dip
Safety edge
operation
dip
OFF
OFF
OFF
NC input, no verification, reversal while
opening and closing (BAR)
OFF
OFF
ON
NC input, no verification, reversal only
when closing, stop when opening (BAR
CL)
OFF
ON
OFF
NC input, with verification, reversal
while opening and closing (BAR TEST)
OFF
ON
ON
NC input, with verification, reversal only
when closing, stop when opening (BAR
CL TEST)
ON
OFF
OFF
8K2 input, reversal when opening and
closing (BAR 8K2)
ON
OFF
ON
8K2 input, reversal only when closing,
stop when opening (BAR CL 8K2)
75
FAULT 2
Test input for safety devices connected to BAR / BAR CL
A
nt
enna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s
range is limited, move the antenna to a more suitable position.
#
SHIELD
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE “A” - PARAMETERS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
TRIMMER
Parameter
+
min.
+
max.
+
default
Description
T1
Automatic
closing time [s]
0
120
0
Waiting time before automatic closing.
NOTE: Set to 0 if not used.
T2
Work time [s]
5
120
50%
SHYRA AC SL
Sets the motor working time (from 0 to 90s), after which the motors stop.
In the case where electrical limit switches are used, add a few extra seconds after the gate leaf
stopping time.
SHYRA AC BA
Motor(s) work time set to 10 seconds.
trimmer at minimum: input 60-61 CLOSE.
trimmer at maximum: input 60-61 START.
TABLE “B” - LOGICS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
DIP
Logic
Default
Cross out
setting used
Description
1
Transmitter
programming
ON
ON
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
OFF
Disables wireless memorizing of transmitters and automatic addition of clones.
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
2
BAR / 8K2
OFF
ON
Input configured as Bar 8k2 (Fig.g). Input for resistive edge 8K2.
The command reverses movement for 1 sec.
OFF
Input configured as Bar, safety edge (Fig.g).
The command reverses movement for 1 sec..
3
Photocell input
check
OFF
ON
Enable safety check on the PHOT input. (Fig.g)
OFF
Safety check on PHOT input not enabled. (Fig.g)
4
Edge input check
OFF
ON
Enable safety check on the BAR input. (Fig.g)
OFF
Safety check on BAR input not enabled. (Fig.g)
SHYRA
-
23