6
111660 Rev C 5-13-14
The Error Messages.
See Figure 5.
When an error message appears, there is a fault
condition in the dispenser. Use the dispenser
diagnostics to determine the problem. Please refer to
page 53 “How to Use Diagnostics”.
NOTE:
When an error message appears the
dispenser can be reset by turning any pump
handle on and back off.
The Power Failure Message.
See Figure 6.
The Power Fail message occurs when the power has
been interrupted or turned off to the dispenser. If the
power is turned off and the P Fail message does not
appear, the charge is low on the 12-volt battery.
Replace the battery. Failure to replace the battery could
result in loss of dispenser electronic totals and stand
alone operating data.
Totals Switch.
See Figure 7.
The totals switch is a magnetic reed switch. The switch
is located directly behind the (Gallons, Liters) screen on
the Main Display Area. See Figure 7 .
To enter the totals mode hold the black Access Magnet
over the “Gallons” (Liters) print beside the Main Display.
This will display all Mode 1, Mode 2, and Mode 26 shift
totals. Once the totals mode is entered, the next totals
are displayed “tapping” the magnet over the
“Gallons” (Liters) print beside the Main Display. By
successively “tapping” over the “Gallons” (Liters) print, all
totals can be displayed. If the magnet is not “tapped”
over the “Gallons” (Liters) print for 30 seconds, the
display returns to idle. See Menu Code 1 and 26 for
more information.
NOTE: If a pump handle is turned on during this
operation, the display returns to idle.
The Last Sale Recall Switch.
See Figure 7.
The Last Sale Recall switch is similar to the Totals
Switch except it is placed behind the Total Sale Text
(Sale $). If power to the dispenser is interrupted, the
money and volume totals can be accessed, as well as
the current sale information. Just hold it over the Total
Sale Text (Sale $) for approximately 2 seconds. The last
sale in progress will display for 20 seconds. Holding the
magnet over the Total Sale Text (Sale$) successively
will bring up the last sale information every 20 seconds.
For complete information, see “How to Retrieve The Last
Sale During a Power Failure,” Page 16.
Figure 5
Pulser
Error
Figure 6
P-Fail
Figure 7
Access Magnet
0.00
0.000
Reed Switch for gaining
access to Totals.
Reed Switch for the Last
Sale Recall Switch.
Pump Control Devices (Cont’d)