33
111660 Rev C 5-13-14
How To Program Submerged Pump Precharge Time
Menu Code 12
The dispenser software is capable of programming the “time delay” circuits for the main control valves to
prevent the leak detector from obtaining a false reading. The submerged pump is energized as soon as
the pump handle is put in the
ON
position and the fueling position is authorized.
The main control valves can be programmed to energize from 1 to 9 seconds after the start of the reset
cycle. This allows the leak detector time to determine whether or not a leak is present. If no leak is
detected, it will allow the flow of fuel.
To program the number of seconds between the time the
submerged pump comes on and the main control valve
turns on, follow this procedure:
1. After the Manager’s Mode has been accessed, press
the number 1 and 2, then the
MODE
button on the
keypad. The price display shows the dispenser is in
Menu Code 12. See Figure 12.1.
If the dispenser has not been programmed since it
came from the factory, the number 2 appears in the
main display. This is the two second default setting.
2. To change the setting, use the 1 through 9 buttons on
the keypad to enter a time delay value in seconds.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
3. When the correct number appears in the volume
display, press the
ENTER
button to save the setting.
4. Press
the
CANCEL
button to exit this menu code.
5. If this is a two sided dispenser, changing one side
will automatically change the second side to the same
value as the first.
PrECH6
2
Figure 12.1
COdE
12
How to Program the Dispenser for Operation