27
111660 Rev C 5-13-14
If the blender was turned ON Figure 7.7 appears next.
This allows the Manager to program the blend ratio of
the center product position. The “A” product ratio is
entered for the percentage of Product A to be
blended. The dispenser calculates the percentage of
product C to be blended but is not displayed.
If the dispenser has not been programmed since it came
from the factory, the number 50 appears in the main
display. This is the default setting. See Figure 7.7.
In addition to the standard 50:50 blend ratio, other blend
ratios are programmable by qualified Bennett Service
contractors from 0:100 to 100:0. Note:1-4%, and 96-99%
are not programmable values.
10. To change the setting, use the 0 through 9 buttons on
the keypad to enter a new blend ratio. For example:
To set a 40:60 blend ratio, enter 40
To set a 30:70 blend ratio, enter 30
NOTE: If an error is made, press the correct number.
The new number replaces the error.
11. When the correct option number appears in the main
display, press the
ENTER
button to save the selection
and Figure 7.8 appears.
If the dispenser has not been programmed since it
came from the factory, the number 10 appears in the
main display. This is the default setting. See Figure
7.8.
This allows the Manager to select an allowable range
of octane rating for the blended product. Normal
tolerance* requirements allow the blended product to
be within half an octane rating of the posted blended
octane. For instance, if the posted octane is 89 for
the blended Product B, a test as low as 88.5 or as
high as 89.5 could be within the tolerance
bLEnd
050
Figure 7.7
COdE
7
bLEnd
Err 10
Figure 7.8
COdE
7
bLEnDr
OtHEr
Figure 7.6
COdE
7
How to Program the Dispenser for Operation