35
111660 Rev C 5-13-14
The Flash Option allows the price display for the idle hose
to be programmed to act in one of two different ways.
The choices are:
0 - The price displays are illuminated constantly in
the idle mode.
1 -
Default
The price displays flash at 1 second
intervals in the idle mode.
The Dash option allows the price displays for the
unselected displays to be programmed two different ways.
The choices are:
0 -
Default
All unselected displays become blank
after a hose is selected.
1 - All unselected displays show dashes after a
hose is selected.
The Flip Option allows a two tier price display to be
inverted or “flipped” between the cash and credit price
displays. This option was added to support various POS
systems that display prices opposite of a Verifone Ruby.
Example: TMS MPC. The choices for Flip are:
0 -
Default
The POS sends the credit price to the
top display and cash price to the bottom display.
1 -
FLIPPED
The POS sends the the credit price
to the bottom display and cash to the top display
requiring “FLIP” to be turned on.
The Digit Option is used to program the cpu for a four or
five digit PPV display. The choices are:
0 - Four Digit Display
1 - Five Digit Display
**IMPORTANT: If option 1 is accidentally selected for
a five digit display, on a display only capable of four
digits, the display characters will be unreadable and
programming will be extremely difficult to perform.
Press the CANCEL button on the keypad several
times until “
Side
”
is displayed. Press the +/- key
five times to alternately program the digit function to
option 0 for a four digit display.
How to Select Individual Price Per Volume Display Options
Menu Code 14
The Individual Price Per Volume Displays can be programmed to operate several ways. This Menu
Code programs the operation of the price displays.
FLASH
1
Figure 14.1
COdE
14
dASH
0
Figure 14.2
COdE
14
How to Program the Dispenser for Operation
flip
0
Figure 14.3
COdE
14