18
111660 Rev C 5-13-14
The dispenser has a variety of Menu Codes that are accessed by using the manager’s keypad. Menu
Codes 0, 1, and 2 are accessed by the attendant or the manager to read diagnostic error codes or totals.
The remaining Menu Codes are used by first entering an access code in Menu Code 3. Without the
correct access code, the remaining Menu Codes are hidden. A description of each Menu Code is given
below:
Menu
Code Name
Description
0 Diagnostics
Diagnostic
tests
1
Hose Totals
Reading Money, Volume, Number of Sales, Number of Price Changes
2
View Totalizer Value
Reading Electro-Mechanical Totals Only
3
Manager Access
Entering a four digit code to access remaining Menu Codes
4
Pricing
Program to set price per volume for each hose & one or two tier
pricing
5
Edit Totalizer Value
Entering a value for each Electro-Mechanical Totalizer on the dispenser
6
Programming
Reviewing programming selections or speed programming dispenser
7
Pump Type
Program to set the - Number of Sides, how many Grades, how many
Hoses, Blender present or not, Blend Ratio, Blended Octane Error
Range
8
Decimal Location
Program to change decimal placement for other than U.S. standard
9
No Flow Time Out
Program to set a time for the dispenser to turn off after flow stops
10
Slow Flow Amt
Program to control the slow down limit on a prepay sale
11
Volume Allocation
Program to control maximum volume of a single sale at one pump
12
Pre-charge Time
Program to set the submerged pump pre-charge time
13
Beeper Tone
Program to set beeper tone options
14
Price Display
Program to set the way Price displays operate
15
Fleet Option
Program to set Fleet system interface compatibility
18
Money Totals
Program to set the money totals calculation method
21
Communication Type
Program to set the dispenser in stand alone or console modes
22
Dispenser Address
Program to set the dispenser address
23
Push to Start
Program to set automatic-on nozzles to work with a button requirement
26
Shift Totals
Program to reset shift totals
28
Rounding
Program to set either rounding or truncating the sale amount.
29
Resettable Totals
Entering a value for each meter on the dispenser (volume total)
49
RAM Clear
Perform a RAM Clear on the equipment
99
Unit of Measure
Program to set the dispenser at gallon, liter or centiliter operation,
Viewing E-CAL Values.
Please read the explanation for each menu code for complete information on these options.
How to Prepare the Dispenser for Programming