42
111660 Rev C 5-13-14
How to Set a Dispenser with the Push to Start Option
Menu Code 23
This menu code is used for dispensers with nozzle boots designed with an
automatic on
mechanism.
This menu code allows the manager to program the dispenser to wait for the customer to activate a
button on the dispenser before fuel can be dispensed. The cash/credit buttons, product buttons or a
“Push to Start” button, when equipped, can be programmed to satisfy this requirement. The options are:
0 - Once the dispenser is authorized and the nozzle is removed from the nozzle boot, the
motor turns on immediately. The valves turn on as soon as the dispenser completes the
reset cycle and the pre-charge time is reached.
1 - Once the dispenser is authorized and the nozzle is removed from the nozzle boot, the
motor turns on as soon as a product select button is pushed. The valves turn on as soon as
the dispenser completes the reset cycle and the pre-charge time is reached.
To select a different option in Menu Code 23, follow this
procedure:
1. After the Manager’s Mode has been accessed, press
the number 2 and 3, then the
MODE
button on the key-
pad. The Price display shows the dispenser is in Menu
Code 23.
If the dispenser has not been programmed since it
came from the factory, the number 1 appears in the
main display. This is the default setting. See Figure
23.1.
2. To change the setting, use the 0 or 1 button on the key-
pad to enter a new option.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
3. When the correct option number appears in the main
display, press the
ENTER
button to save the selection
4. Press
the
CANCEL
button to exit this menu code.
5. If this is a two sided dispenser, changing one side
will automatically change the second side to the
same value as the first.
PUSH
Strt 1
Figure 23.1
COdE
23
How to Program the Dispenser for Operation