- 227 -
ENG
Position
Description
Quantity
19
OIL SUMP GASKET
1
20
OIL SUMP
1
21
MAGNETIC CAP
1
STARTING
PHASE SENSOR INSTALLATION/ADJUSTMENT
Fitting:
1. Apply a suitably thick copper scraper shim (x) to keep the
distance for the phase sensor compared to a suitable pickup
for reading the number of revolutions Fig. A.
2. Insert the phase sensor (8) into its housing in the left casing
(10) Fig. A.
3. Tighten the fastening screw (7) to the following torque: B:
T.R.
Torque 12 N*m
Measure:
•
The distance (A) between the phase sensor (8) and the
pick-up on the magnet fl ywheel Fig. C.
NOTE
Use a thickness gauge to take this measurement.
IMPORTANT NOTICE
During measurement, apply or remove scraper shims to reach
the required distance (A).
Thickness
Measure
Scraper thickness (x)
0.20 mm
4. Once the right value has been found, assemble the cap (5)
and the relevant gaskets to the left casing cover (10) Fig. D.
A
X
8
B
7
C
A
8
D
5