Installation EAGLE20/30
Release 11 09/2020
27
1.8
Management interfaces
1.8.1
V.24 interface (external management)
Note:
For information about the position on the device see
A serial interface is provided on the RJ11 socket (V.24 interface) for the local
connection of an external management station (VT100 terminal or PC with
corresponding terminal emulation). This enables you to set up a connection
to the Command Line Interface CLI and to the System Monitor.
The socket housing is electrically connected to the front panel of the device.
The V.24 interface is electrically insulated from the supply voltage.
Figure 1: Pin assignment of the V.24 interface and the DE9 connector
The terminal cable is available as an accessory.
1.8.2
SD card interface
Note:
For information about the position on the device see
The SD card interface allows you to connect the AutoConfiguration Adapter
ACA31 storage medium. This is used for saving/loading the configuration
data and diagnostic information, and for loading the software.
The ACA31 supports the FAT16 file system format exclusively.
VT 100 terminal settings
Speed
9600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DE9
RJ11
DE9