Installation EAGLE20/30
Release 11 09/2020
39
3
Making basic settings
Note:
2 or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Input via the V.24 interface
Input via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the
Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
AutoConfiguration Adapter
Further information on the basic settings of the device can be found in the
user manual.
Default settings
V.24 data rate: 9,600 Baud
Ethernet ports: link status is not evaluated (signal contact)
Optical ports: Full duplex
TP ports: Autonegotiation