Installation EAGLE20/30
Release 11 09/2020
45
Digital input (optional)
Note:
Only for supply voltage with the following characteristic values:
CC
K9
The support of the function depends on the software release. Software
support for the function is unimplemented at the time of printing this
manual.
Climatic
conditions
during
operation
Ambient air temperature
a
Devices with operating temperature
characteristic value S (standard):
0 °C ... +60 °C (+32 °F ... +140 °F)
Devices with operating temperature
characteristic value E and T (extended):
−
40 °C ... +70 °C
b,c
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Climatic
conditions
during storage
Ambient air temperature
d
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
“FAULT”
signal contact
Switching current
max. 1 A, SELV
Switching voltage
max. 60 V DC or max. 30 V AC, SELV
Pollution degree
2
Protection
classes
Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP20
a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
b. Only use the SFP transceiver with the extension “EEC”.
c. +85 °C for 16 hours (tested in accordance with IEC 60068-2-2)
d. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
Maximum permitted input voltage range
−
32 V DC … +32 V DC
Input voltage, low level, status “0”
−
0.3 V DC … +5.0 V DC
Input voltage, high level, status “1”
+11 V DC … +30 V DC
Maximum input current at 24 V input voltage
15 mA
Input characteristic acc. to IEC 61131-2 (current-consuming)
Type 3