50
Inst
allation
EAGLE20/30
Re
lease
11
09/2
020
EN 61000-4-3
80 MHz ... 2700 MHz
—
—
20 V/m
—
IEEE 1613
80 MHz ... 1000 MHz
—
—
—
35 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
AC/DC supply connection
± 2 kV
± 2 kV
± 2 kV
± 4 kV
EN 61000-4-4
IEEE C37.90.1
Data line
± 4 kV
± 1 kV
± 2 kV
± 4 kV
Voltage surges - DC supply connection
EN 61000-4-5
IEEE 1613
line/ground
± 2 kV
± 1 kV
± 2 kV
± 5 kV
EN 61000-4-5
line/line
± 1 kV
± 0.5 kV
± 1 kV
± 1 kV
Voltage surges - AC supply connection
EN 61000-4-5
IEEE 1613
line/ground
± 2 kV
± 1 kV
± 2 kV
± 5 kV
EN 61000-4-5
line/line
± 1 kV
± 0.5 kV
± 1 kV
± 2 kV
Voltage surges - data line
EN 61000-4-5
line/ground
± 1 kV
—
± 2 kV
± 4 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
10 V
10 V
EMC interference
immunity
Standard
applications
Navy applications Railway
applications
Substation
applications
Содержание Hirschmann EAGLE20