Installation and Operation Manual
BEKOKAT
®
V01 /11-046
33 / 88
3.5.4 Incline seat valves (7/8)
In order to ensure the safe operation of the assembly unit (even in the unlikely event of an oil
breakthrough), the incline seat valves V1 and V2 are installed in the inlet and condensate drain
line for automatic shut-off of the compressed air. These are controlled by the measured
temperature in the catalyst bed.
Incline seat valves are engaged via the control valve Y1 (11).
When the incline seat valves V1 and V2 close, then the position indicators of the valves (2)
move down into the drive of the valves.