Installation and Operation Manual
BEKOKAT
®
V01 /11-046
31 / 88
3.5
Description of the components
3.5.1 Heat exchanger plate (1)
The heat exchanger plate is designed as an air-to-air heat exchanger. The cold compressed
air entering into the assembly unit is heated by means of emerging from the reactor
compressed air at high temperatures accordingly. In parallel, the cooling of the escaping
compressed air takes place in the heat exchanger.
3.5.2 Catalytic converter reactor (2)
NOTE
Technical data
The maximum permissible operating pressure is 16 bar.
The maximum permissible operating temperature of the container
tank walls is 300 °C.
The catalytic converter reactor is a pressure device according to PED
2014/68/EU.
The reactor is not designed for pressure cycling.
The removal of seals and labels on safety equipment is prohibited.
3.5.3 Temperature Control Unit (3)
The temperature sensor TT1.1 in the middle of the catalytic bed continuously measures the
operating temperature and the temperature control unit regulates the catalytic temperature to
the Setpoint temperature of + 150 °C set on the control element. The actual temperature in the
middle of the tank is shown on the display A1 of the control box.