3.5.6 Safety equipment against temperature overruns (5/6)
The reactor tank has been calculated and tested for a maximum operating temperature of +
300 °C. There are 2 safety thermostats installed on the outer wall of the container.
The temperature monitor TW (5) is installed in the upper part of the reactor on the tank wall
and opens when a set limit value of + 260 °C is exceeded
In this situation, the indicator light H2 turns yellow and the alarm F01 is displayed.
After falling below the limit value, the reset is carried out by means of automatic RESET TW
F01.