Installation and Operation Manual
BEKOKAT
®
V01 /11-046
77 / 88
6.10 RESET for time relay K1T
There is a contactor K3A in the e-box (see E-plan attached). At a reactor temperature of> +
130 °C ... + 150 °C it is possible, in consultation with the service technician of
BEKO
TECHNOLOGIES, to actuate the RESET key of the K3A and thus to bridge the time
relay.
When the RESET button is pressed, the incline seat valves V1 and V2 open. This can be
utilised to wait for e.g. shorten a short-term voltage drop.
R
RESET button for relay K1T
DANGER Observe temperature
At a reactor temperature of <+ 130 °C ... + 150 °C the time of K1T of
approx. 5 hours must be kept.
Only after reaching a reactor temperature> + 130 °C ... + 150 °C can
the possibility of the RESET key (R) on the relay K3A be used.
A reactor temperature
> + 250 °C
handelt es sich um einen
fault
and
the system must be shut down and checked.
The RESET button (R) must
not
be pressed in this case.
Commissioning of the
BEKOKAT
®
is only permitted after inspection
and approval by authorised skilled technical personnel.